Evidence map›Paper›PMID 40949781›Full record

ArticleFrontiers in surgery2025

Application of mirror reconstruction and 3D printing technology in the treatment of Sanders type IV calcaneal fractures.

Xiong Liao, Jianliang Deng, Di You

Abstract read
In one paragraph

Article in Frontiers in surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Xiong LiaoDepartment of Orthopedics and Traumatology, The Affiliated Changsha Central Hospital, Hengyang Medical School, University of South China, Changsha, Hunan, China.
Jianliang DengDepartment of Orthopedics and Traumatology, The Affiliated Changsha Central Hospital, Hengyang Medical School, University of South China, Changsha, Hunan, China.
Di YouDepartment of Orthopedics and Traumatology, The Affiliated Changsha Central Hospital, Hengyang Medical School, University of South China, Changsha, Hunan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To explore the clinical efficacy of an integrated workflow combining mirror reconstruction and 3D printing for Sanders type IV calcaneal fractures-a severely comminuted subtype with limited evidence-based solutions and to explore a new individualized and accurate method for the treatment of Sanders type IV calcaneal fractures. Methods: A retrospective analysis of the clinical data of 20 patients with Sanders type IV calcaneal fractures who were treated with mirror image reconstruction and 3D printing technology in the Department of Orthopedics of our hospital from April 2021 to July 2023 was performed. There were 16 males and 4 females; their ages ranged from 38 to 62 years, with an average of 48.00 ± 1.84 years. All patients underwent clinical and radiological evaluation. The operation time, intraoperative blood loss, fracture healing time, and surgical complications were recorded. The width and height of the calcaneus, Böhler angle, and gissane angle were measured and compared before surgery, after surgery, and at the last follow-up. At the final follow-up, the American Orthopedic Foot and Ankle Society (AOFAS) ankle and hindfoot scores were used to evaluate hindfoot function, and the pain visual analog scale (VAS) was used to evaluate pain. Results: All 20 patients in this group underwent successful operations. The operation time ranged from 52 to 75 min, with an average of 59.55 ± 1.52 min. The volume of intraoperative blood loss ranged from 35 to 50 ml, with an average of 41.00 ± 1.16 ml. All patients received satisfactory follow-up, with follow-up times ranging from 12 to 38 months and an average of 16.55 ± 1.34 months. All the fractures healed, and the healing time ranged from 10 to 13 weeks, with an average of 11.55 ± 0.211 weeks. Two patients developed symptoms of sural nerve injury after surgery, two patients developed subtalar joint stiffness after surgery, and two patients developed traumatic arthritis changes in the calcaneellar joint during the 1-year follow-up. At the final follow-up, the calcaneal length, width, height, Böhler angle, and Gissane angle were significantly greater than those before surgery ( Conclusion: This integrated approach enables precise reduction with superior short-term outcomes, though long-term validation requires RCTs.

Indexed as

3D printingcalcaneusfracturefracture fixationmirror reconstruction

Identifiers

PMID40949781
PMCPMC12424589

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.