Clinical application study of a novel fully automatic erythrocyte osmotic fragility analysis system.

Zixin Deng, Yi Li, Zhizhi Xiang, Yi Liu, Jingbo Tang, Song Zhang, Guangchao Zang, Yingying Gao, Lei Ma

Abstract read
In one paragraph

Article in Biochemistry and biophysics reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Zixin DengBiomedical Innovation and Entrepreneurship Practice Base, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, China.
Yi LiBiomedical Innovation and Entrepreneurship Practice Base, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, China.
Zhizhi XiangBiomedical Innovation and Entrepreneurship Practice Base, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, China.
Yi LiuSchool of Medical Technology, Chongqing Medical and Pharmaceutical College, Chongqing, China.
Jingbo TangChongqing Lifotronic Innovation Biotechnology Co.,Ltd., Chongqing, China.
Song ZhangChongqing Lifotronic Innovation Biotechnology Co.,Ltd., Chongqing, China.
Guangchao ZangBiomedical Innovation and Entrepreneurship Practice Base, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, China.
Yingying GaoDepartment of Medical Laboratory, Banan Hospital Affiliated to Chongqing Medical University, Chongqing, China.
Lei MaDepartment of Medical Laboratory, Affiliated Hospital of Chongqing Medical and Pharmaceutical College, Chongqing Medical and Pharmaceutical College, Chongqing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Existing erythrocyte osmotic fragility test (EFT) methods are constrained by subjectivity, poor reproducibility, and lack of standardization, limiting their clinical utility in thalassemia screening. This study evaluates the RA-800 Plus, a novel fully automated EFT analyzer, as a scalable tool for thalassemia screening and aims to establish reference intervals for healthy individuals. By addressing the key limitations of manual EFTs, this work seeks to promote methodological innovation and enable standardized, high-throughput screening in diverse clinical settings. Methods: EFTs were performed on 273 healthy adults via an RA-800 Plus analyzer. The light scattering turbidity method was employed to establish a reference interval within the normal range. The neonatal samples were tested in the same way to determine the newborn-specific range. Moreover, 97 samples underwent dual tests of RA-800 Plus analysis and the gold standard (genetic testing) to evaluate the diagnostic performance. A total of 103 pairs of samples were detected and compared via an automated system and the traditional manual direct colorimetric method, further verifying the consistency of the two methods. The effects of anticoagulant type, sample storage, and rewarming were also investigated. Results: RA-800 Plus demonstrated high reliability, with minimal influence from anticoagulants and sample handling conditions. The analyzer showed an 84 % detection rate for β-thalassemia, indicating superior effectiveness for β-thalassemia screening. The test results were consistent with the manual method (Kappa ≥0.6). ROC curve analysis confirmed the suitability of both methods for thalassemia screening, with AUCs of 0.91 for β-thalassemia and 0.72 for α-thalassemia. Conclusions: The RA-800 Plus offers a fully automated, reliable, and clinically viable alternative for thalassemia screening, particularly for β-thalassemia. Its stability, accuracy, and ease of use make it a valuable tool for improving thalassemia diagnostics.

Indexed as

AccuracyAutomated analyzerErythrocyte fragility test (EFT)Instrument performanceThalassemia screening