Evidence map›Paper›PMID 40948692›Full record

ArticleIndoor air2025

Estimation of the Number of Subslab Soil Gas Samples to Collect to Characterize Vapor Intrusion Under a Large Building.

John H Zimmerman, Alan Williams, Brian Schumacher, Chris Lutes, Rohit Warrier, Laurent Levy, Gwen Buckley, Brian Cosky, Chase Holton, Kate Bronstein

Abstract read
In one paragraph

Article in Indoor air, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

John H ZimmermanUS Environmental Protection Agency (EPA), Office of Research and Development (ORD), Center for Environmental Measurement & Modeling (CEMM), Watershed and Ecosystem Characterization Division (WECD), Research Triangle Park, North Carolina, USA.ORCID 0000-0002-0909-0079
Alan WilliamsUS Environmental Protection Agency (EPA), Office of Research and Development (ORD), Center for Environmental Measurement & Modeling (CEMM), Watershed and Ecosystem Characterization Division (WECD), Research Triangle Park, North Carolina, USA.ORCID 0000-0002-9078-179X
Brian SchumacherUS EPA, ORD, CEMM, Ecosystem Processes Division, Athens, Georgia, USA.ORCID 0000-0001-8202-2630
Chris LutesFederal and Environmental Solutions, Jacobs Engineering Group Inc., Cary, North Carolina, USA.ORCID 0000-0001-5546-2649
Rohit WarrierCenter for Environmental Health, Risk, and Sustainability, RTI International, Research Triangle Park, North Carolina, USA.
Laurent LevyFederal and Environmental Solutions, Jacobs Engineering Group Inc., Boston, Massachusetts, USA.ORCID 0000-0002-0784-1887
Gwen BuckleyFederal and Environmental Solutions, Jacobs Engineering Group Inc., Virginia Beach, Virginia, USA.
Brian CoskyFederal and Environmental Solutions, Jacobs Engineering Group Inc., Indianapolis, Indiana, USA.
Chase HoltonDenver Office, GSI Environmental Inc., Lakewood, Colorado, USA.ORCID 0000-0001-5589-656X
Kate BronsteinCenter for Environmental Health, Risk, and Sustainability, RTI International, Research Triangle Park, North Carolina, USA.ORCID 0000-0003-3546-369X

Funding

EPA EP-C-16-016Intramural EPA EPA999999
6 · The paper itself

Abstract

Upward migration of vapors from subsurface contamination into overlying buildings is known as vapor intrusion (VI) and can result in exposure of the building's inhabitants to contaminants that can cause detrimental health effects. Multiple lines of evidence (MLEs), such as groundwater, soil, soil gas, and indoor air volatile organic compound (VOC) concentrations, are used to evaluate a building for VI and potential risk of occupant exposure. Background sources of contaminants contained within a building can result in a false positive determination of VI and installation of mitigation systems that are not needed. To avoid a false positive determination, some VI guidance documents recommend the prioritization of subslab soil gas (SSSG) concentrations over indoor air concentrations for determination of a VI issue. If the SSSG VOC concentrations are above a determined concentration, then VI is assumed to be possible; depending upon the concentration, immediate mitigation may be required. The major challenge to characterizing VI potential is the number of samples needed to confidently assess VI exposures due to the extreme variability in vapor concentrations across both time and space, and this study explores variability in SSSG and how many SSSG samples are needed. To address this issue, SSSG samples were collected between December 2020 and April 2022 from six commercial buildings in Fairbanks, Alaska, and between May 2019 and June 2021 from a large, compartmentalized warehouse at a coastal site in Virginia. Types of samples collected included indoor air; outdoor air; SSSG; soil gas; radon; differential pressure; indoor and outdoor temperature; heating, ventilation, and air conditioning (HVAC) parameters; and other environmental factors. To illustrate how these results can inform estimates of expected SSSG variability and thus the number of samples required to characterize variability, the temporal and spatial variabilities of the results observed at the test sites were used as a "similar population" to estimate necessary sample sizes for characterization of VI levels and to explore how temporal and spatial factors may influence estimates. The estimated SSSG sample requirement ranged from 1 to 80 samples and thus showed the substantial sensitivity of the systematic project planning equation to cases in which the action level and the average concentration are similar. We recommend that the estimated number of samples generated from the collected data for the buildings should only be used as a starting point for planning purposes. The number of SSSG samples to initially collect at a large building to characterize VI can be calculated, but the actual number should include adjustments for features of a building (e.g., past usage, separate foundations, and footers) and conditions at a site (e.g., proximity to source and depth to groundwater) that may alter the required number of SSSG samples.

Indexed as

spatial variabilitysubslab soil gastemporal variabilityvapor intrusion

Identifiers

PMID40948692
PMCPMC12425155

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.