ArticleMeasurement science & technology2025
Dynamic laboratory x-ray phase-contrast microtomography with structure-based prior regularisation.
Article in Measurement science & technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
X-ray microtomography is a versatile tool allowing the measurement of the 3D structure of optically thick samples. As a non-destructive technique, it is readily adapted to 4D imaging, where a sample can be monitored over time, and especially in conjunction with the application of external stimuli. To apply this technique with the limited x-ray flux available at a conventional laboratory source, we leverage the contrast enhancement of free-space propagation phase-contrast imaging, achieving an increase in contrast-to-noise ratio (CNR) of 5.8x. Furthermore, we combine this with iterative reconstruction, using regularisation by a structure-based prior from a high-quality reference scan of the object. This combination of phase-contrast imaging and iterative reconstruction leads to a 29.2x improvement in CNR compared to the conventional reconstruction. This enables fully dynamic x-ray microtomography, with a temporal resolution of 9 s at a voxel size of 10.5 μm. We use this to measure the movement of a waterfront in the fine vessels of a wooden skewer, as a representative example of dynamic system evolving on the scale of tens of seconds.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.