ArticleImaging neuroscience (Cambridge, Mass.)2025
Automated generation of epilepsy surgery resection masks: The RAMPS pipeline.
Article in Imaging neuroscience (Cambridge, Mass.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- AI in epilepsy neuroimaging.Current opinion in neurology · 2026Review
- Multimodal integration of magnetic resonance imaging and intracranial electroencephalographic abnormalities in temporal lobe epilepsy surgery.Epilepsia · 2026Article
- Combined impact of gray and superficial white matter abnormalities: Implications for epilepsy surgery.Epilepsia · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
MRI-based delineation of brain tissue removed by epilepsy surgery can be challenging due to post-operative brain shift. In consequence, most studies use manual approaches which are prohibitively time-consuming for large sample sizes, require expertise, and can be prone to errors. We propose RAMPS (Resections And Masks in Preoperative Space), an automated pipeline to generate a 3D resection mask of pre-operative tissue. Our pipeline leverages existing software including FreeSurfer, SynthStrip, Sythnseg and ANTs to generate a mask in the same space as the patient's pre-operative T1 weighted MRI. We compare our automated masks against manually drawn masks and two other existing pipelines (Epic-CHOP and ResectVol). Comparing to manual masks (N = 87), RAMPS achieved a median (IQR) dice similarity of 0.86 (0.078) in temporal lobe resections, and 0.72 (0.32) in extratemporal resections. In comparison to other pipelines, RAMPS had higher dice similarities (N = 62) (RAMPS: 0.86, Epic-CHOP: 0.72, ResectVol: 0.72). We release a user-friendly, easy-to-use pipeline, RAMPS, open source for accurate delineation of resected tissue.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.