Dynamic functional examination of the peritoneal dialysis catheter using color Doppler ultrasound. In vitro technical evaluation and in vivo application.

Matthias Zeiler, Anastasia Mancini, Antonio Federico, Valentina Ramazzotti, Simona Silvestri, Leonardo Spatola, Stefano Santarelli, Antonio Granata

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in Journal of nephrology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Matthias ZeilerNephrology and Dialysis Unit, Peritoneal Dialysis Section, Ospedale "C. E G. Mazzoni" Hospital, Via Degli Iris N. 1, 63100, Ascoli Piceno, Italy. mrhz1@yahoo.com.ORCID http://orcid.org/0000-0001-6066-6144
Anastasia ManciniNephrology and Dialysis Unit, Peritoneal Dialysis Section, Ospedale "C. E G. Mazzoni" Hospital, Via Degli Iris N. 1, 63100, Ascoli Piceno, Italy.
Antonio FedericoNephrology and Dialysis Unit, "Carlo Urbani" Hospital, Jesi, Italy.
Valentina RamazzottiNephrology and Dialysis Unit, "Carlo Urbani" Hospital, Jesi, Italy.ORCID http://orcid.org/0000-0002-8767-6761
Simona SilvestriNephrology and Dialysis Unit, Peritoneal Dialysis Section, Ospedale "C. E G. Mazzoni" Hospital, Via Degli Iris N. 1, 63100, Ascoli Piceno, Italy.
Leonardo SpatolaNephrology and Dialysis Unit, "Sant'Antonio Abate" Hospital, Erice, Italy.ORCID http://orcid.org/0000-0002-8883-4776
Stefano SantarelliNephrology and Dialysis Unit, "Carlo Urbani" Hospital, Jesi, Italy.
Antonio GranataNephrology and Dialysis Unit, "Cannizzaro" Hospital, Catania, Italy.ORCID http://orcid.org/0000-0002-7026-3952

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPeritoneal dialysis catheter malfunction compromises dialysis adequacy. Standard imaging methods in the case of peritoneal catheter malfunction include abdominal X-ray, fluoroscopic catheter peritoneography, and computed tomography. Ultrasound has only recently been utilized to evaluate the intraperitoneal part of the catheter. In clinical routine, catheter function is assessed by the time needed to fill or drain a defined quantity of peritoneal dialysis fluid. Visual functional testing of the catheter can be performed by fluoroscopy or by contrast-enhanced ultrasound. We developed and tested a color Doppler ultrasound technique for dynamic imaging of the peritoneal catheter based on signal generation by dialysis fluid flow.

methodsThe feasibility of the color Doppler approach was evaluated utilizing a phantom. Furthermore, the technique was applied in 28 peritoneal dialysis patients, most of whom presented peritoneal catheter malfunction.

resultsColor Doppler examination improved the catheter visualization, especially in cases in which the catheter is embedded between the intestinal loops. Furthermore, this technique highlighted catheter side hole occlusions by adhesions or intraluminal thrombi. The examination can be performed either during filling or draining of dialysis fluid.

conclusionsThe color Doppler ultrasound technique appears to be helpful in identifying problem-solving strategies in malfunctioning peritoneal catheters.

Indexed as

Catheters, IndwellingPeritoneal DialysisUltrasonography, Doppler, ColorAdultAgedEquipment FailureFeasibility StudiesFemaleHumansMaleMiddle AgedPhantoms, ImagingPredictive Value of TestsCatheter flowColor Doppler ultrasoundDiagnosticsImagingMalfunctionPeritoneal dialysis