Evidence map›Paper›PMID 40942850›Full record

ArticleSensors (Basel, Switzerland)2025

A Formative Assessment System in Baduanjin Physical Education Based on Inertial Measurement Unit Motion Capture.

Xinyi Ma, Mingrui Shao, Xiaowei Feng, Weiping Du, Qing Yi, Puyan Chi, Hai Li

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xinyi MaSchool of Physical Education, Shanghai Normal University, Shanghai 201418, China.ORCID 0009-0006-8219-8189
Mingrui ShaoSchool of Physical Education, Shanghai Normal University, Shanghai 201418, China.ORCID 0009-0003-6720-9909
Xiaowei FengSchool of Physical Education, Hainan Normal University, Haikou 571158, China.ORCID 0000-0002-3006-4545
Weiping DuSchool of Physical Education, Ningxia Normal University, Guyuan 756099, China.
Qing YiFaculty of Sports and Exercise Science, University of Malaya, Kuala Lumpur 50603, Malaysia.
Puyan ChiDepartment of Physical Education, Shanghai Maritime University, Shanghai 201306, China.
Hai LiFaculty of Sports and Exercise Science, University of Malaya, Kuala Lumpur 50603, Malaysia.ORCID 0000-0002-1160-3777

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Traditional assessment methods in physical education often emphasize final grades, lacking real-time monitoring and feedback during the learning process. To address this limitation and enhance the formative evaluation of student performance, this study proposes a real-time assessment system for Baduanjin instruction in physical education, utilizing a commercially available inertial measurement unit-based motion capture device. The system was developed in four stages. First, a dataset was created by recruiting 20 university students and one expert physical education instructor. Participants were asked to perform standardized Baduanjin routines while wearing wireless inertial measurement unit sensors on key body joints. The collected kinematic data, sampled at 100 Hz, included joint angles and movement trajectories. Second, preprocessing and feature extraction techniques were applied to the raw data to construct a labeled dataset for training. Third, supervised machine learning algorithms were used to build models for motion type recognition and motion accuracy evaluation. Model performance was assessed using cross-validation and compared with expert evaluations. Finally, a user-facing formative assessment system was developed and tested in a controlled classroom environment. The system demonstrated a high motion recognition accuracy of 99.77%, and the correlation coefficient between system-assessed motion accuracy and expert ratings exceeded 0.80, indicating strong validity. The results demonstrate that the formative assessment system built on inertial measurement unit is appropriate for the Baduanjin physical education.

Indexed as

Baduanijnformative assessmentinertial measurement unitmotion capturephysical education

Identifiers

PMID40942850
PMCPMC12430958

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.