Evidence map›Paper›PMID 40942474›Full record

ArticleMaterials (Basel, Switzerland)2025

Effects of Two Dental Implant Micromotor Systems for Dental Implant Placement on Implant Stability and Removal Torque: An Animal Experiment.

Keunbada Son, Young-Tak Son, Sung-Min Hwang, Jae Mok Lee, Jin-Wook Kim, Kyu-Bok Lee

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Keunbada SonAdvanced Dental Device Development Institute (A3DI), Kyungpook National University, Daegu 41940, Republic of Korea.ORCID 0000-0002-3177-8005
Young-Tak SonAdvanced Dental Device Development Institute (A3DI), Kyungpook National University, Daegu 41940, Republic of Korea.ORCID 0000-0001-8893-5369
Sung-Min HwangDepartment of Periodontology, School of Dentistry, Kyungpook National University, Daegu 41566, Republic of Korea.ORCID 0000-0002-2701-4854
Jae Mok LeeDepartment of Periodontology, School of Dentistry, Kyungpook National University, Daegu 41566, Republic of Korea.
Jin-Wook KimDepartment of Oral & Maxillofacial Surgery, School of Dentistry, Kyungpook National University, Daegu 41566, Republic of Korea.
Kyu-Bok LeeDepartment of Dental Science, Graduate School, Kyungpook National University, Daegu 41940, Republic of Korea.ORCID 0000-0002-1838-7229

Funding

Korea Evaluation Institute of Industrial Technology 20018114National Research Foundation of Korea no. 2022R1C1C2007040
6 · The paper itself

Abstract

This in vivo animal study aimed to evaluate the effects of two different implant placement micromotor systems on implant stability and removal torque. In a within-animal crossover design, twenty titanium implants (AnyOne fixture; internal type; diameter, 3.5 mm; length, 7.0 mm; Megagen, Daegu, Republic of Korea) were placed in the tibiae of five rabbits using a conventional micromotor system (NSK group: SurgicPro+; NSK, Kanuma, Japan) and a diode laser-integrated micromotor system (SAESHIN group: BLP 10; Saeshin, Daegu, Republic of Korea). Resonance frequency analysis provided the implant stability quotient (ISQ) immediately after placement and at four weeks. Micro-computed tomography quantified the bone-implant interface gap (BIG). Removal torque was measured at sacrifice. Linear mixed-effects models with a random intercept for rabbit generated adjusted means with 95% confidence intervals (CIs) (α = 0.05). Equivalence for the four-week ISQ used two one-sided tests with a margin of ±5 ISQ. The SAESHIN group achieved a higher immediate ISQ than the NSK group (difference =+6.9 ISQ; 95% CI +1.3-+12.5;

Indexed as

bone–implant interface gapdental implant micromotorimplant stability quotientmicro-computed tomographyremoval torqueresonance frequency analysis

Identifiers

PMID40942474
PMCPMC12429704

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.