Improved fault-clearing strategy for large renewable energy systems using advanced optimization and FLC.

Abdulaziz Almalaq, Khalid Alqunun, Rabeh Abbassi, Shady H E Abdel Aleem, Rania G Mohamed

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Abdulaziz AlmalaqDepartment of Electrical Engineering, College of Engineering, University of Hail, Hail, 55473, Saudi Arabia.
Khalid AlqununDepartment of Electrical Engineering, College of Engineering, University of Hail, Hail, 55473, Saudi Arabia.
Rabeh AbbassiDepartment of Electrical Engineering, College of Engineering, University of Hail, Hail, 55473, Saudi Arabia.
Shady H E Abdel AleemBasic Sciences Council, Academy of Scientific Research and Technology, Cairo, 11516, Egypt.
Rania G MohamedDepartment of Electrical Engineering, Institute of Aviation Engineering and Technology, Giza, 12658, Egypt. raniagamalmohamed2021@gmail.com.ORCID http://orcid.org/0000-0002-6394-3829

Funding

This research has been funded by the Scientific Research Deanship at the University of Hail - Saudi Arabia through project number "RG-23 191". "RG-23 191".
6 · The paper itself

Abstract

This paper introduces a novel fault-clearing strategy for large-scale hybrid photovoltaic/wind/battery power systems (HPVWBPS). A modified fault-clearing strategy (MFCS) is developed using the Manta ray foraging optimization (MRFO) algorithm and a fuzzy logic controller (FLC). The FLC enhances decision-making in fault-clearing, while MRFO determines the optimal FLC gains for photovoltaic (PV) and wind turbine (WT)-based power plants, ensuring maximum power point tracking (MPPT). Additionally, MRFO optimizes power dispatch during faults by considering solar and wind resource availability, battery energy levels, and load demand. By mimicking the foraging behavior of manta rays, the algorithm efficiently balances power generation and consumption, minimizing fault impact. The proposed strategy is evaluated through extensive simulations on a large-scale HPVWBPS using MATLAB/SIMULINK 2022(b). The proposed method enhances system stability and fault recovery by determining optimal controller gains using the MRFO algorithm. A detailed comparison of key performance metrics, rise time (RT), settling time (ST), maximum overshoot (MOST), and optimal gains was conducted for both voltage and current regulators under four configurations: PI-based GWO, PI-based MRFO, FLC-based GWO, and FLC-based MRFO. This assessment isolates the effects of both the controller type and the optimization algorithm. The results show that MRFO consistently outperforms GWO in both PI and FLC frameworks. MRFO provides faster convergence, reduced overshoot, and shorter settling times. For the current regulator, the MRFO-FLC combination achieves an ST of 1.0020 ms, compared to 1.0033 ms for the PI-GWO controller, marking a 1.3% improvement. The RT is reduced from 3.2755 μs to 2.1885 μs, a 33.2% decrease. MOST is also lowered from 143.22% to 140.12%, a 2.17% reduction. These improvements enhance the regulator's dynamic performance and reduce component stress. The voltage regulator shows similar trends. The ST drops slightly from 1.0052 ms to 1.0051 ms. RT improves from 8.1978 μs to 8.1878 μs. MOST decreases from 86.79% to 86.57%. Though the changes are smaller, they remain consistent across all metrics. FLC-based controllers outperform PI-based controllers in terms of dynamic response and stability. They better handle system nonlinearities and delays, making them more suitable for hybrid renewable energy systems. Among all configurations tested, the FLC-MRFO setup delivers the best overall performance. Its superior adaptability, reduced overshoot, and faster response validate its effectiveness for robust and efficient power system control.

Indexed as

Fuzzy logic controllerHybrid systemsMaximum power point trackingModified fault clearing strategyMRFOPhotovoltaicWind turbines

Identifiers

PMID40940433
PMCPMC12432210

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.