ArticleMedical physics2025

Automatic catheter digitization in breast brachytherapy.

Sébastien Quetin, Hossein Jafarzadeh, Jonathan Kalinowski, Hamed Bekerat, Boris Bahoric, Farhad Maleki, Shirin A Enger

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trends in brachytherapy utilization in Canada from 2011 to 2020.Physics and imaging in radiation oncology · 2026
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sébastien QuetinMedical Physics Unit, Department of Oncology, McGill University, Montreal, Canada.
Hossein JafarzadehMedical Physics Unit, Department of Oncology, McGill University, Montreal, Canada.
Jonathan KalinowskiMedical Physics Unit, Department of Oncology, McGill University, Montreal, Canada.
Hamed BekeratDepartment of Radiation Oncology, Jewish General Hospital, McGill University, Montreal, Canada.
Boris BahoricDepartment of Radiation Oncology, Jewish General Hospital, McGill University, Montreal, Canada.
Farhad MalekiDepartment of Computer Science, University of Calgary, Calgary, Canada.
Shirin A EngerMedical Physics Unit, Department of Oncology, McGill University, Montreal, Canada.

Funding

Canada Research Chairs 252135CIHR 170620Natural Sciences and Engineering Research Council of Canada 170620
6 · The paper itself

Abstract

backgroundHigh dose rate (HDR) brachytherapy requires clinicians to digitize catheters manually. This process is time-consuming, complex, and depends heavily on clinical experience-especially in breast cancer cases, where catheters may be inserted at varying angles and orientations due to an irregular anatomy. PURPOSE: This study is the first to automate catheter digitization specifically for breast HDR brachytherapy, emphasizing the unique challenges associated with this treatment site. It also introduces a pipeline that automatically digitizes catheters, generates dwell positions, and calculates the delivered dose for new breast cancer patients.

methodsTreatment data from 117 breast cancer patients treated with HDR brachytherapy were used. Pseudo-contours for the catheters were created from the treatment digitization points and divided into three classes: catheter body, catheter head, and catheter tip. An nnU-Net pipeline was trained to segment the pseudo-contours on treatment planning computed tomography images of 88 patients (training and validation). Then, pseudo-contours were digitized by separating the catheters into connected components. Predicted catheters with an unusual volume were flagged for manual review. A custom algorithm was designed to report and separate connected components containing colliding catheters. Finally, a spline was fitted to every separated catheter, and the tip was identified on the spline using the tip contour prediction. Dwell positions were placed from the created tip at a regular step size extracted from the DICOM plan file. Distance from each dwell position used during the clinical treatment to the fitted spline (shaft distance) was computed, as well as the distance from the treatment tip to the one identified by our pipeline. Dwell times from the clinical plan were assigned to the nearest generated dwell positions. TG-43 dose in water was computed analytically, and the absorbed dose in the medium was predicted using a published AI-based dose prediction model. Dosimetric comparison between the clinically delivered plan dose and the created automated plan dose was evaluated regarding dosimetric indices percent error.

resultsOur pipeline was used to digitize 408 catheters on a test set of 29 patients. Shaft distance was on average

conclusionsOur pipeline is the first to automate the digitization of catheters for breast brachytherapy, as well as the first to generate dwell positions and predict corresponding AI-based absorbed dose to medium based on automatically digitized catheters. The automatically digitized catheters are in excellent agreement with the manually digitized ones while more accurately reflecting their true anatomical shape.

Indexed as

BrachytherapyBreast NeoplasmsCathetersImage Processing, Computer-AssistedAutomationFemaleHumansRadiotherapy DosageRadiotherapy Planning, Computer-Assistedautomatic catheter digitizationbreast brachytherapydeep learning

Identifiers

PMID40940288
PMCPMC12431940

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.