ArticleMedical physics2025
Image-domain metal artifact reduction in low-energy VMI using high-energy regional prior.
Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Image-domain metal artifact reduction in low-energy VMI using high-energy regional prior.Medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
backgroundMetal artifacts degrade the clinical utility of virtual monochromatic images (VMIs), particularly in low energy levels. Nevertheless, low-energy VMIs have essential clinical applications, such as reducing the volume of iodinated contrast material administered, salvaging poorly attenuated contrast-enhanced CT studies, and analyzing arterial vasculature during the venous phase. Conventional metal artifact reduction algorithms may introduce new artifacts and obscure soft tissue details. PURPOSE: The aim of this study is to develop a practical image-domain solution for significantly reducing the metal artifacts in low-energy VMIs while preserving the clarity of soft tissues and metal boundaries.
methodsA mapping model was developed to establish a relationship between optimal VMI and the material basis images (MBIs) in artifact-free regions. This model was subsequently used to correct artifact-affected regions in MBIs. Finally, artifact-reduced low-energy VMIs were synthesized from the updated MBIs. The approach, referred to as regional model-based metal artifact reduction (rMAR), utilized the mapping model to effectively reduce metal artifacts. To validate the efficacy of the proposed method, both phantom and patient data acquired from Philips scanner were used. The scanner's built-in metal artifact reduction for orthopedic implants, known as OMAR, was employed. Comprehensive comparisons were conducted among four image processing strategies: VMI alone, VMI combined with OMAR (VMI + OMAR), VMI combined with the proposed rMAR (VMI + rMAR), and a combination of all three methods (VMI + OMAR + rMAR). Evaluations were performed using visual assessment, line profile analysis, and measurement of the ∆CT number.
resultsHigh-energy VMIs exhibit significantly fewer metal artifacts compared to those at low energy levels, as demonstrated in both phantom and patient results. Although conventional metal artifact reduction algorithms can mitigate the existing artifacts, they often introduce new ones. In contrast, the proposed rMAR method effectively reduces artifacts in low-energy VMIs, achieving improved image quality without introducing new artifacts. In specific cases, such as postoperative VMIs of hip prosthesis implants, the combined VMI + OMAR + rMAR approach demonstrates superior metal artifact reduction compared to either OMAR or rMAR alone. Quantitative line profile analysis indicated that the proposed rMAR method produced images with artifact levels more closely resembling the ground truth than those processed with OMAR. The ΔCT number was significantly lower in the images processed with rMAR than in those processed with OMAR.
conclusionThe proposed rMAR method effectively achieves metal artifact reduction, particularly in low-energy VMIs, while preserving the clarity of soft tissues and metal boundaries. Consequently, the diagnostic value of low-energy VMIs containing metal implants is enhanced.