Evidence map›Paper›PMID 40938373›Full record

ArticleNeuroradiology2025

Hemorheological changes induced by Flow-diverting stents at the aneurysm neck in cerebral circulation.

Osman Ergin, Ali Bahadir Olcay, Alperen Elek, Ismail Oran

Abstract read
PubMed Publisher
In one paragraph

Article in Neuroradiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Osman ErginDepartment of Mechanical Engineering, Yeditepe University, Istanbul, Turkey.
Ali Bahadir OlcayDepartment of Mechanical Engineering, Yeditepe University, Istanbul, Turkey.
Alperen ElekDepartment of Interventional Radiology, Faculty of Medicine, Ege University, Izmir, Turkey. alperenelek13@gmail.com.
Ismail OranDepartment of Interventional Radiology, Faculty of Medicine, Ege University, Izmir, Turkey. ismailoran@gmail.com.

Funding

TUBITAK (The Scientific and Technological Research Council of Turkey) 117M491
6 · The paper itself

Abstract

purposeThis study investigates the hemodynamic effects of flow diverter stent (FDS) implantation on intracranial aneurysms, focusing on shear stress and shear strain rates at the neck region between the stent struts. MATERIALS AND

methodsPatient-specific geometries were reconstructed from Digital Subtraction Angiography (DSA) cone-beam source images and processed to accurately model arterial anatomy and aneurysm morphology. FDS designs with 48- and 64-wire configurations were modeled while maintaining consistent porosity (65%) across all stents. Blood flow simulations were performed using computational fluid dynamics (CFD) to analyze shear stress and strain rates between the stent struts after FDS implantation.

resultsCFD analysis using DSA images from five patients-three with distal internal carotid artery sidewall aneurysms and two with middle cerebral artery bifurcation aneurysms-demonstrated that, prior to stent implantation, shear stress and strain rate values at the aneurysm inlet were generally below established thresholds throughout the cardiac cycle. Following FDS implantation, those values measured between stent struts increased significantly, with some patients exceeding thresholds either throughout the entire cycle or only during systole. Both 48- and 64-wire FDS models exhibited significantly higher shear forces compared to the non-stent models; however, no significant differences were observed between the two stent designs. Aneurysm volume showed a statistically significant positive correlation with the maximum and average shear forces generated through the stent struts.

conclusionFDS implantation consistently induces supra-physiologic shear stress and shear strain rates across the aneurysm neck between the stent struts. The measured shear forces are significantly correlated with aneurysm volume.

Indexed as

Cerebrovascular CirculationIntracranial AneurysmStentsAgedAngiography, Digital SubtractionBlood Flow VelocityCerebral AngiographyComputer SimulationFemaleHemorheologyHumansMaleMiddle AgedModels, CardiovascularStress, MechanicalTreatment OutcomeComputational fluid dynamicsFlow diverter stentVon willebrand disease

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.