ArticleNeuroradiology2025
Hemorheological changes induced by Flow-diverting stents at the aneurysm neck in cerebral circulation.
Article in Neuroradiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
purposeThis study investigates the hemodynamic effects of flow diverter stent (FDS) implantation on intracranial aneurysms, focusing on shear stress and shear strain rates at the neck region between the stent struts. MATERIALS AND
methodsPatient-specific geometries were reconstructed from Digital Subtraction Angiography (DSA) cone-beam source images and processed to accurately model arterial anatomy and aneurysm morphology. FDS designs with 48- and 64-wire configurations were modeled while maintaining consistent porosity (65%) across all stents. Blood flow simulations were performed using computational fluid dynamics (CFD) to analyze shear stress and strain rates between the stent struts after FDS implantation.
resultsCFD analysis using DSA images from five patients-three with distal internal carotid artery sidewall aneurysms and two with middle cerebral artery bifurcation aneurysms-demonstrated that, prior to stent implantation, shear stress and strain rate values at the aneurysm inlet were generally below established thresholds throughout the cardiac cycle. Following FDS implantation, those values measured between stent struts increased significantly, with some patients exceeding thresholds either throughout the entire cycle or only during systole. Both 48- and 64-wire FDS models exhibited significantly higher shear forces compared to the non-stent models; however, no significant differences were observed between the two stent designs. Aneurysm volume showed a statistically significant positive correlation with the maximum and average shear forces generated through the stent struts.
conclusionFDS implantation consistently induces supra-physiologic shear stress and shear strain rates across the aneurysm neck between the stent struts. The measured shear forces are significantly correlated with aneurysm volume.
Indexed as
Identifiers
40938373What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.