Evidence map›Paper›PMID 40937296›Full record

ArticleSA journal of radiology2025

Magnetic resonance fistulography with percutaneous jelly: A novel and cost-effective technique.

Umamaheshwari K Basavaraju, Shivani S Ravate Patil, N Manupratap, B Tejesh, Shubha Tavarakere Shamasundara, Larryth Reuben

Abstract read
In one paragraph

Article in SA journal of radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Umamaheshwari K BasavarajuDepartment of Radiodiagnosis, Mysore Medical College and Research Institute, Mysore, India.ORCID https://orcid.org/0009-0005-6786-2259
Shivani S Ravate PatilDepartment of Radiodiagnosis, Mysore Medical College and Research Institute, Mysore, India.ORCID https://orcid.org/0009-0008-0849-235X
N ManupratapDepartment of Radiodiagnosis, Mysore Medical College and Research Institute, Mysore, India.ORCID https://orcid.org/0009-0007-5113-5414
B TejeshDepartment of Radiodiagnosis, Mysore Medical College and Research Institute, Mysore, India.ORCID https://orcid.org/0009-0001-5797-3263
Shubha Tavarakere ShamasundaraDepartment of Radiodiagnosis, Mysore Medical College and Research Institute, Mysore, India.ORCID https://orcid.org/0009-0008-6772-4552
Larryth ReubenDepartment of Radiodiagnosis, Mysore Medical College and Research Institute, Mysore, India.ORCID https://orcid.org/0009-0008-3511-2033

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Magnetic resonance fistulography (MRF) is a key non-invasive imaging technique for mapping perianal fistulas before surgery. The instillation of aqueous jelly, like ultrasound gel, enhances the signal-to-noise ratio, improving image quality and MRF accuracy. This low-cost approach improves accessibility, especially in resource-limited settings, while ensuring patient comfort and safety. Objectives: To determine the impact of aqueous jelly on the accuracy of MRF in identifying fistulous tracts, internal openings, secondary ramifications and abscesses and the quality of visualisation of MRF with and without jelly instillation. Method: A cross-sectional study at Krishna Rajendra and Cheluvamba Hospitals, Mysore (October 2024-March 2025), included 40 patients with perianal fistulas. Magnetic resonance fistulography was performed using a 1.5 Tesla uMR 570 system, without and with 5 mL - 7 mL of sterile aqueous jelly instilled percutaneously. MRI findings were compared with intraoperative results. Data were analysed using Statistical Package for the Social Sciences (SPSS) to assess sensitivity, specificity and accuracy. Results: Magnetic resonance fistulography with gel improved visualisation, identifying internal openings in 92.5% of cases (vs. 24% without gel) and secondary tracts in 40% (vs. 17.5%). The accuracy compared to surgery was 97.5% for internal openings, 95% for secondary tracts, 97.5% for abscesses and 100% for supralevator extension. Conclusion: Aqueous jelly instillation enhances MRF accuracy, improving fistula visualisation and aiding in preoperative planning. This technique reduces recurrence and incontinence risk and supports more accurate surgical interventions. Contribution: This study re-emphasises the value of aqueous jelly in improving diagnostic accuracy and accessibility, especially in resource-limited settings.

Indexed as

aqueous gel instillationfistula-in-anointernal openingsMR fistulogramsecondary ramification

Identifiers

PMID40937296
PMCPMC12421450

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.