ArticleJournal of orthopaedic case reports2025
Unusual Case of Failure of Tibial Polyethylene Insert Locking Mechanism in a Design of Cruciate Retaining Total Knee Arthroplasty - A Case Report.
Article in Journal of orthopaedic case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Bilateral total knee arthroplasty (TKA) with a cruciate-retaining (CR) design is a widely performed procedure, but complications involving the prosthesis's locking mechanism are rare. We present a case of locking clip dislodgement in a Zimmer Biomet Vanguard prosthesis, highlighting a rare cause of post-operative swelling and hardware impingement. Case Report: A patient, 1 year after undergoing bilateral TKA, presented with a four-month history of medially prominent knee swelling. Clinical examination and radiographs revealed impinging hardware and confirmed the failure of the locking mechanism, with the locking clip visible as a dislodged entity. Following a negative work-up for infection, the patient was taken for revision surgery. The locking clip was found in the subcutaneous tissue, having buttonholed through the retinaculum. To facilitate access, the posterior cruciate ligament was released, a quadriceps snip was performed, and the anterior superficial medial collateral ligament was subperiosteally released. The original polyethylene liner was replaced with a new anterior stabilized (AS) polyethylene liner of the same thickness and secured with a new locking clip. Intraoperative cultures were negative. The post-operative course was uneventful, with the patient achieving full range of motion within 1 week. Conclusion: This case report underscores that locking mechanism failure should be considered in the differential diagnosis of post-TKA knee swelling and pain. The use of an AS polyethylene liner with a new locking clip proved to be a successful revision strategy, leading to a favorable functional outcome.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.