Evidence map›Paper›PMID 40936019›Full record

ArticleJournal of imaging informatics in medicine2026

U-ConvNext: A Robust Approach to Glioma Segmentation in Intraoperative Ultrasound.

Amir M Vahdani, Mahdiyeh Rahmani, Ahmad Pour-Rashidi, Alireza Ahmadian, Parastoo Farnia

Abstract read
In one paragraph

Article in Journal of imaging informatics in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Amir M VahdaniResearch Center for Biomedical Technologies and Robotics (RCBTR), Advanced Medical Technologies and Equipment Institute (AMTEI), Imam Khomeini Hospital Complex , Tehran University of Medical Sciences (TUMS), Tehran, Iran.
Mahdiyeh RahmaniResearch Center for Biomedical Technologies and Robotics (RCBTR), Advanced Medical Technologies and Equipment Institute (AMTEI), Imam Khomeini Hospital Complex , Tehran University of Medical Sciences (TUMS), Tehran, Iran.
Ahmad Pour-RashidiDepartment of Radiology, Northwestern University, Chicago, IL, USA.
Alireza AhmadianResearch Center for Biomedical Technologies and Robotics (RCBTR), Advanced Medical Technologies and Equipment Institute (AMTEI), Imam Khomeini Hospital Complex , Tehran University of Medical Sciences (TUMS), Tehran, Iran.
Parastoo FarniaDepartment of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences (TUMS), Tehran, Iran. p-farnia@sina.tums.ac.ir.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intraoperative tumor imaging is critical to achieving maximal safe resection during neurosurgery, especially for low-grade glioma resection. Given the convenience of ultrasound as an intraoperative imaging modality, but also the limitations of the ultrasound modality and the time-consuming process of manual tumor segmentation, we propose a learning-based model for the accurate segmentation of low-grade gliomas in ultrasound images. We developed a novel U-net-based architecture adopting the block architecture of the ConvNext V2 model, titled U-ConvNext, which also incorporates various architectural improvements including global response normalization, fine-tuned kernel sizes, and inception layers. We also adopted the CutMix data augmentation technique for semantic segmentation, aiming for enhanced texture detection. Conformal segmentation, a novel approach to conformal prediction for binary semantic segmentation, was also developed for uncertainty quantification, providing calibrated measures of model uncertainty in a visual format. The proposed models were trained and evaluated on three subsets of images in the RESECT dataset and achieved hold-out test Dice scores of 84.63%, 74.52%, and 90.82% on the "before," "during," and "after" subsets, respectively, which indicates increases of ~ 13-31% compared to the state of the art. Furthermore, external evaluation on the ReMIND dataset indicated a robust performance (dice score of 79.17% [95% CI: 77.82-81.62] and only a moderate decline of < 3% in expected calibration error. Our approach integrates various innovations in model design, model training, and uncertainty quantification, achieving improved results on the segmentation of low-grade glioma in ultrasound images during neurosurgery.

Indexed as

Brain NeoplasmsGliomaImage Interpretation, Computer-AssistedDeep LearningHumansUltrasonographyConformal predictionDeep learningGliomaIntraoperative ultrasoundSegmentationUncertainty quantification

Identifiers

PMID40936019
PMCPMC13230339

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.