Evidence map›Paper›PMID 40934222›Full record

ArticlePloS one2025

Mechanics of knee meniscus results from precise balance between material microstructure and synovial fluid viscosity.

Camilo A S Afanador, Stéphane Urcun, Ivo F Sbalzarini, Stéphane P A Bordas, Olga Barrera, Mohammad Mahdi Rajabi, Romain Seil, Anas Obeidat

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Camilo A S AfanadorDepartment of Engineering, Institute of Computational Engineering, University of Luxembourg, Esch sur Alzette, Luxembourg.
Stéphane UrcunDepartment of Engineering, Institute of Computational Engineering, University of Luxembourg, Esch sur Alzette, Luxembourg.ORCID 0000-0002-5164-5904
Ivo F SbalzariniDresden University of Technology, Faculty of Computer Science, Dresden, Germany.ORCID 0000-0003-4414-4340
Stéphane P A BordasDepartment of Engineering, Institute of Computational Engineering, University of Luxembourg, Esch sur Alzette, Luxembourg.ORCID 0000-0001-7622-2193
Olga BarreraSchool of Engineering Computing and Mathematics, Oxford Brookes University, Oxford, United Kingdom.
Mohammad Mahdi RajabiDepartment of Engineering, Institute of Computational Engineering, University of Luxembourg, Esch sur Alzette, Luxembourg.
Romain SeilDepartment of Orthopaedic Surgery, Centre Hospitalier de Luxembourg - Clinique d'Eich, Luxembourg, Luxembourg.
Anas ObeidatDepartment of Engineering, Institute of Computational Engineering, University of Luxembourg, Esch sur Alzette, Luxembourg.ORCID 0000-0002-4580-1640

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The meniscus plays a crucial role in the biomechanics of the knee, serving as load transmitter and reducing friction between joints. Understanding the biomechanics of the meniscus is essential to effective treatment of knee injuries and degenerative conditions. This study aims to elucidate the relationship between the porous microstructure of the human knee meniscus and its biomechanical function, specifically focusing on fluid dynamics at the pore scale. Here, we use two central-meniscus samples extracted from a human knee and reconstruct high-resolution geometry models from [Formula: see text]-CT scans. By eroding the channels of the original meniscus geometry, we simulate perturbed microstructures with varying porosities ( 53% to 80%), whilst preserving the connectivity of the porous structure. We numerically solve for the fluid dynamics in the meniscus using a mesh-free particle method, considering various inlet pressure conditions, characterising the fluid flow within the microstructures. The results of the original microstructure associated with a physiological dynamic viscosity of synovial fluid are in accordance with biophysical experiments on menisci. Furthermore, the eroded microstructure with a 33% increase in porosity exhibited a remarkable 120% increase in flow velocity. This emphasises the sensitivity of meniscus physiology to the porous microstructure, showing that detailed computational models can explore physiological and pathological conditions, advancing further knee biomechanics research.

Indexed as

Knee JointMeniscusSynovial FluidBiomechanical PhenomenaHumansHydrodynamicsPorosityViscosity

Identifiers

PMID40934222
PMCPMC12425204

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.