Evidence map›Paper›PMID 40932006›Full record

ArticleActa oncologica (Stockholm, Sweden)2025

Time efficiency, geometric accuracy, and clinical impact of AI-assisted contouring of organs at risk in head and neck cancer radiotherapy.

Johan M Søbstad, Turid H Sulen, Helge E S Pettersen, Grete May Engeseth, Lukas A Hirschi, Camilla H Stokkevåg

Abstract read
In one paragraph

Article in Acta oncologica (Stockholm, Sweden), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Johan M SøbstadCancer Clinic, Haukeland University Hospital, Bergen, Norway. johan.martin.sobstad@helse-bergen.no.ORCID 0009-0007-1408-825X
Turid H SulenCancer Clinic, Haukeland University Hospital, Bergen, Norway.ORCID 0000-0001-5124-7933
Helge E S PettersenCancer Clinic, Haukeland University Hospital, Bergen, Norway.ORCID 0000-0003-4879-771X
Grete May EngesethCancer Clinic, Haukeland University Hospital, Bergen, Norway; Department of Life Sciences and Health, Oslo Metropolitan University, Olso, Norway.ORCID 0000-0003-0233-9836
Lukas A HirschiCancer Clinic, Haukeland University Hospital, Bergen, Norway.ORCID 0009-0000-7662-7668
Camilla H StokkevågCancer Clinic, Haukeland University Hospital, Bergen, Norway; Department of Physics and Technology, University of Bergen, Bergen, Norway.ORCID 0000-0001-6352-4571

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeEnsuring the reliability and accuracy of artificial intelligence (AI)-generated contours is paramount, as discrepancies could lead to inadequate protection of healthy tissues. With increasing clinical workload, the aim of this study was to assess the time-saving potential of AI-assisted organs at risk (OAR) contouring in head and neck cancer (HNC) treatment planning, while also evaluating geometric accuracy, variability, and dosimetric impact. Patient/material and methods: Twenty patients had 12 OAR contoured by 11 certified dosimetrists and ARTplan (Therapanacea), including the brainstem, cochleas, larynx, mandible, oral cavity, parotid glands, pharynx constrictor muscles, spinal cord, right submandibular gland and thyroid gland. Comparisons were made using geometrical metrics, including Mean Surface Distance, Dice Similarity Coefficient (DSC), Hausdorff Distance, Volume Difference, and Centre of Mass Difference, as well as relevant dose-volume metrics, and total contouring time.

resultsMedian manual contouring time of the OARs was 55 (range: 17-151) minutes per patient, while adjusted AI-based structures required 17 (7-42), resulting in 69% time saved. For manual, adjusted and AI-contours, the mean DSC were generally high, averaging 0.85, 0.86, and 0.81 respectively across the evaluated structures. Notably, variability was lowest for the AI and adjusted contours. Average mean and max dose differences were acceptably low (<3.2 Gy) for all OARs.

interpretationThe results support the integration of AI-based contouring in HNC treatment planning. With minor adjustments, the contours achieve very good clinical quality and demonstrate improved consistency compared to manual contours, while significantly reducing contouring time.

Indexed as

Artificial IntelligenceHead and Neck NeoplasmsOrgans at RiskRadiotherapy Planning, Computer-AssistedFemaleHumansMaleMiddle AgedRadiotherapy DosageRadiotherapy, Intensity-ModulatedTime Factors

Identifiers

PMID40932006
PMCPMC12439213

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.