ArticleMagma (New York, N.Y.)2026

Improving magnetic field homogeneity in prostate MR imaging and spectroscopy using an add-on local external shim coil array.

Angeliki Stamatelatou, Carlijn Tenbergen, Sahar Nassirpour, Paul Chang, Jack van Asten, Arend Heerschap, Tom Scheenen

Abstract read
In one paragraph

Article in Magma (New York, N.Y.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Angeliki StamatelatouDepartment of Medical Imaging, (766), Radboud University Medical Center, Geert Grooteplein 10Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, the Netherlands. angeliki.stamatelatou@radboudumc.nl.ORCID http://orcid.org/0000-0002-3956-8731
Carlijn TenbergenDepartment of Medical Imaging, (766), Radboud University Medical Center, Geert Grooteplein 10Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, the Netherlands.ORCID http://orcid.org/0000-0001-7169-4204
Sahar NassirpourMR Shim GmbH, Ferdinand-Lassalle-Straße 36, 72770, Reutlingen, Germany.
Paul ChangMR Shim GmbH, Ferdinand-Lassalle-Straße 36, 72770, Reutlingen, Germany.
Jack van AstenDepartment of Medical Imaging, (766), Radboud University Medical Center, Geert Grooteplein 10Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, the Netherlands.
Arend HeerschapDepartment of Medical Imaging, (766), Radboud University Medical Center, Geert Grooteplein 10Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, the Netherlands.ORCID http://orcid.org/0000-0001-9930-4562
Tom ScheenenDepartment of Medical Imaging, (766), Radboud University Medical Center, Geert Grooteplein 10Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, the Netherlands.ORCID http://orcid.org/0000-0002-4468-1480

Funding

H2020 Marie Skłodowska-Curie Actions 813120
6 · The paper itself

Abstract

objectiveTo improve B

methodsIn vivo prostate imaging was performed in seven healthy volunteers (mean age: 40.7 years) without bowel preparation. A simulation study determined the most robust configuration of the add-on shim coil together with shim coils from the MR system. The combination of the add-on shim coil array with 1st-order shims of the MR scanner was used and compared to the MR system's reference standard of conventional 1st and 2nd-order shimming. Performance was evaluated using the standard deviation (SD) of off-resonance frequencies (ΔB

resultsOverall, improvements were made with the combination of coils, with DSC rising from 0.90 ± 0.02 to 0.92 ± 0.02 (p = 0.01), a reduction in the SD of ΔB

conclusionA dedicated external shim coil array can improve B0 homogeneity in the prostate, enhancing image quality and precision in multi-parametric MRI.

Indexed as

Magnetic Resonance ImagingProstateAdultAlgorithmsComputer SimulationDiffusion Magnetic Resonance ImagingEquipment DesignHealthy VolunteersHumansImage Processing, Computer-AssistedMagnetic FieldsMagnetic Resonance SpectroscopyMaleMiddle AgedPhantoms, ImagingProstatic NeoplasmsB0 shimmingDiffusion-weighted imagingProstateProton MR spectroscopy and spectroscopic imaging

Identifiers

PMID40931281
PMCPMC12901270

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.