SynthesisThe Cochrane database of systematic reviews2025
Prognostic models for radiation-induced complications after radiotherapy in head and neck cancer patients.
Synthesis in The Cochrane database of systematic reviews, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Prognostic models for radiation-induced complications after radiotherapy in head and neck cancer patients.The Cochrane database of systematic reviews · 2025Pooled it
- High-Recall Biomedical Language Models for Radiation Oncology Evidence Synthesis: An Integrated Systematic Review of Prediction Models for Radiotherapy-Induced Complications in Nasopharyngeal Carcinoma.Life (Basel, Switzerland) · 2026Review
- Risk factors for severe radiation-induced dermatitis in nasopharyngeal carcinoma patients undergoing radiotherapy.Frontiers in oncology · 2026Article
- Prediction Models for Acute and Chronic Postoperative Pain in Patients with Cancer: A Systematic Review and Meta-Analysis.Journal of pain research · 2026Review
- A Case Series on the Combined Use of Zinc L-Carnosine and Nd:YAG Photobiomodulation for Radiation-Induced Oral Mucositis: Pain Reduction and Lesion Improvement.Case reports in dentistry · 2026Article
- Evaluation of semi-automated record screening methods for systematic reviews of prognosis studies and intervention studies.Research synthesis methods · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundRadiotherapy is the mainstay of treatment for head and neck cancer (HNC) but may induce various side effects on surrounding normal tissues. To reach an optimal balance between tumour control and toxicity prevention, normal tissue complication probability (NTCP) models have been reported to predict the risk of radiation-induced side effects in patients with HNC. However, the quality of study design, conduct, and analysis (i.e. risk of bias (ROB)), as well as the predictive performance of these models, remains to be evaluated.
objectivesTo identify, describe and appraise NTCP models to predict the risk of radiation-induced side effects in patients with HNC. SEARCH
methodsWe searched Ovid MEDLINE, Embase and the World Health Organization International Clinical Trials Registry Platform from conception to January 2024. In addition, we screened references cited in the retrieved articles. SELECTION CRITERIA: Two review authors independently included articles reporting on the development and external validation of NTCP models to predict any type of radiation-induced side effects in patients with HNC. DATA COLLECTION AND ANALYSIS: One reviewer extracted data from each article based on the Checklist for Critical Appraisal and Data Extraction for Systematic Reviews of Prediction Modelling Studies and assessed their applicability and ROB using the Prediction model ROB Assessment Tool, while another reviewer carefully verified the results. For models externally validated at least twice for the same outcome as their original developmental study, we performed qualitative analyses of the model performance. The GRADE system was not applied, since it has not been established for reviews of prognostic model studies. MAIN
resultsAmongst 592 models developed from 143 articles, including 140,767 HNC patients, only 49 (8%) models from six articles were judged to have low ROB and low concerns for applicability. No external validation was performed for 480 models (81%). For the remaining 112 models and six additional models which were not eligible for the present review, 152 external validations were performed in 34,304 patients with HNC in 41 articles. The results of models externally validated at least twice are discussed below. Models for xerostomia Amongst 275 models for xerostomia, two models were externally validated at least twice. The Beetz 2012b model for xerostomia six months after radiotherapy was validated in two studies. C-statistics ranged from 0.70 to 0.74. Calibration performance was reported in one study. One validation study was rated as having low ROB in all domains, while the other was rated as having high ROB in the analysis domain. The Cavallo 2021 model for acute xerostomia during radiotherapy for patients with nasopharyngeal cancer was externally validated in the same study, using two different types of cohorts. C-statistics ranged from 0.68 to 0.73 and calibration plots were reported in both cohorts. Both validations were rated as having unclear ROB in the participants' domain because no detailed information about recruiting was provided. Models for dysphagia Amongst 86 models for dysphagia, two models were externally validated at least twice. The Christianen 2012 model for dysphagia six months after radiotherapy was validated in five studies. C-statistics ranged from 0.66 to 0.75. Calibration performance was assessed in all of them, while four of them were rated as having high ROB in the analysis domain due to the small sample size. The Wopken 2014b model for tube feeding dependence six months after radiotherapy was validated in three external validation studies. C-statistics ranged from 0.79 to 0.95, while calibration was evaluated in all studies. Due to the small size of the validation datasets, they were judged as having high ROB in the analysis domain. Models for hypothyroidism Of 66 models for hypothyroidism, two models were externally validated at least twice. In addition, there was another model which was not originally developed for patients with HNC, but validated in this domain. The Boomsma 2012 for hypothyroidism within two years after radiotherapy was externally validated in two studies. C-statistics ranged from 0.64 to 0.74, while only one study reported its calibration performance. Both validation studies were rated as having high ROB in the analysis domain. The Ronjom 2013 model for radiation-induced hypothyroidism was validated in three studies. C-statistics ranged from 0.65 to 0.69 and calibration plots were reported in only one study. Two validation studies were judged as having high and the other was rated as having unclear ROB in the analysis domain. The Cella 2012 model was originally developed to predict radiation-induced hypothyroidism in patients with Hodgkin's lymphoma. In two validation studies in patients with HNC, c-statistics ranged from 0.65 to 0.68, but calibration performance was not reported. One validation study was rated as having a high ROB and the other was rated as being unclear in the analysis domain. Models for temporal lobe injury Amongst six models for temporal lobe injury, two were externally validated at least twice. The OuYang 2023 model, using deep learning in patients with nasopharyngeal cancer, was validated in the same paper using two different cohorts. C-statistics ranged from 0.80 to 0.82, while calibration performance was assessed in both cohorts. Both validations were judged as having low ROB in all domains. The Wen 2021 model was developed to predict temporal lobe injury in newly diagnosed nasopharyngeal cancer patients. The model was validated by OuYang 2023 using two cohorts. C-statistics ranged from 0.77 to 0.79, while calibration performance was not reported. Both validations were judged as having unclear ROB in the analysis domain. Models for outcomes related to hoarseness, fatigue, nausea-vomiting, throat pain, aspiration No models were externally validated at least twice. AUTHORS'
conclusionsAmongst 592 developed models, a limited number had adequate quality. Only one-fifth were externally validated, of which, only nine models at least twice. These nine models showed acceptable discriminative performance at external validation. However, their calibration performance was not always reported. Furthermore, most validation studies were judged as having high ROB, mainly due to problems in the analysis domain. In conclusion, this review shows the need for more external validation studies before the implementation of developed models in clinical practice and improvement of the quality of conducting and reporting of prediction model studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.