ArticleJournal of the American Society for Mass Spectrometry2025
Enhanced Charge-Sensitive Amplifier Performance Leads to Substantially Reduced CD-MS Measurement Times for Charge State Resolution.
Article in Journal of the American Society for Mass Spectrometry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Analyses of Individual Singly Charged Ions Using a High-Field Orbitrap Analyzer.Analytical chemistry · 2026Article
- Optimization of Radially Segmented Ion Mirrors for High Resolution Charge Detection Mass Spectrometry.Journal of the American Society for Mass Spectrometry · 2026Article
- Coupling Drift Tube Ion Mobility Measurements with Charge Detection Mass Spectrometry for the Analysis of Virus-like Particles and Other Megadalton-Sized Ions.Analytical chemistry · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
In charge detection mass spectrometry (CD-MS) ions are trapped in an electrostatic linear ion trap (ELIT) where they oscillate back and forth through a conducting cylinder. The oscillating ions induce a periodic charge separation that is detected by a charge sensitive amplifier (CSA) connected to the cylinder. The resulting time domain signal is analyzed using short-time Fourier transforms to give the mass-to-charge ratio and charge for each ion, which are then multiplied to give the mass. For ions to be assigned to the correct integer charge states with a low error rate, the charge should be measured with a precision of <0.2 e (elementary charges). Electrical noise reduces the precision of the charge measurement. However, the effect of the noise can be ameliorated by signal averaging, and the measurement time can, in principle, be increased to achieve a precision of <0.2 e. Previously, through optimized ELIT design and improvements to the CSA, the measurement time (with a cryogenically cooled input JFET) required to achieve a charge precision of <0.2 e was reduced by a factor of 2, from 3 s to 1.5 s. In this study, further improvements in JFET selection, capacitance matching, and cryogenic cooling has allowed us to further reduce the electrical noise so that the target precision of <0.2 e can now be achieved for mAb MSQC4 in 600-700 ms with the input JFET cryogenically cooled, and in 900-1000 ms with the input JFET at room temperature. This performance upgrade cuts the overall time for high-resolution charge measurements by more than another factor of 2. For a measurement time of 100 ms, the charge RMSD is 0.51 e with cryogenic cooling. The results presented here further cements CD-MS with an ELIT as the fastest and most accurate approach to single ion MS measurements.
Identifiers