Evidence map›Paper›PMID 40924946›Full record

ArticleJournal of the American Society for Mass Spectrometry2025

Enhanced Charge-Sensitive Amplifier Performance Leads to Substantially Reduced CD-MS Measurement Times for Charge State Resolution.

Raj A Parikh, Andrew W Alexander, Martin F Jarrold

Abstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Raj A ParikhChemistry Department, Indiana University, 800 E Kirkwood Ave, Bloomington, Indiana 47405.
Andrew W AlexanderChemistry Department, Indiana University, 800 E Kirkwood Ave, Bloomington, Indiana 47405.
Martin F JarroldChemistry Department, Indiana University, 800 E Kirkwood Ave, Bloomington, Indiana 47405.ORCID 0000-0001-7084-176X

Funding

Developing High-Resolution Ion Mobility Spectrometry-Charge Detection-Mass Spectrometry for Rapid Analysis in the Megadalton to Gigadalton RegimeR01GM131100 · NIGMS · TRUSTEES OF INDIANA UNIVERSITY · PI CLEMMER, DAVID E., JARROLD, MARTIN F · 2019 to 2022
$2.1M
Advancing High-Resolution Charge Detection-Mass SpectrometryR01GM155650 · NIGMS · TRUSTEES OF INDIANA UNIVERSITY · PI MARTIN F JARROLD · 2024 to 2026
$811k
NIGMS NIH HHS R01 GM131100NIGMS NIH HHS R01 GM155650
6 · The paper itself

Abstract

In charge detection mass spectrometry (CD-MS) ions are trapped in an electrostatic linear ion trap (ELIT) where they oscillate back and forth through a conducting cylinder. The oscillating ions induce a periodic charge separation that is detected by a charge sensitive amplifier (CSA) connected to the cylinder. The resulting time domain signal is analyzed using short-time Fourier transforms to give the mass-to-charge ratio and charge for each ion, which are then multiplied to give the mass. For ions to be assigned to the correct integer charge states with a low error rate, the charge should be measured with a precision of <0.2 e (elementary charges). Electrical noise reduces the precision of the charge measurement. However, the effect of the noise can be ameliorated by signal averaging, and the measurement time can, in principle, be increased to achieve a precision of <0.2 e. Previously, through optimized ELIT design and improvements to the CSA, the measurement time (with a cryogenically cooled input JFET) required to achieve a charge precision of <0.2 e was reduced by a factor of 2, from 3 s to 1.5 s. In this study, further improvements in JFET selection, capacitance matching, and cryogenic cooling has allowed us to further reduce the electrical noise so that the target precision of <0.2 e can now be achieved for mAb MSQC4 in 600-700 ms with the input JFET cryogenically cooled, and in 900-1000 ms with the input JFET at room temperature. This performance upgrade cuts the overall time for high-resolution charge measurements by more than another factor of 2. For a measurement time of 100 ms, the charge RMSD is 0.51 e with cryogenic cooling. The results presented here further cements CD-MS with an ELIT as the fastest and most accurate approach to single ion MS measurements.