ArticlePloS one2025
A volumetric modulated arc therapy-based dynamic conformal arc technique with limited monitor units (VMATliMU) to reduce multileaf collimator interplay effects: A computational phantom study for stage I non-small-cell lung cancer.
Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Volumetric modulated arc therapy (VMAT) for lung cancer involves complex multileaf collimator (MLC) motion, which increases sensitivity to interplay effects with tumour motion. Current dynamic conformal arc methods address this issue but may limit the achievable dose distribution optimisation compared with standard VMAT. This study examined the clinical utility of a VMAT technique with monitor unit limits (VMATliMU) to mimic conformal arc delivery and reduce interplay effects while maintaining plan quality. VMATliMU was implemented by applying monitor unit limitations during VMAT reoptimisation to minimise MLC encroachment into target volumes. Using mesh-type reference computational phantom CT images, treatment plans were generated for a simulated stage I lung cancer case prescribed to 45 Gy in three fractions. VMATliMU, conventional VMAT, VMAT with leaf speed limitations, dynamic conformal arc therapy, and constant dynamic conformal arc therapy were compared. Plans were optimised for multiple isodose line prescriptions (50%, 60%, 70%, 80%, and 90%) to investigate the impact of dose distribution. Evaluation parameters included MLC positional accuracy using area difference ratios, dosimetric indices, gradient metrics, and organ-at-risk doses. VMATliMU prevented MLC encroachment into the internal target volume across 60%-90% isodose lines, showing superior MLC accuracy compared with other methods. At the challenging 50% isodose line, VMATliMU had 4.5 times less intrusion than VMAT with leaf speed limits. VMAT plans had better dosimetric indices than dynamic conformal arc plans. VMATliMU reduced monitor units by 5.1%-19.2% across prescriptions. All plans met the clinical dose constraints, with the aortic arch below tolerance and acceptable lung doses. VMATliMU combines VMAT's dosimetric benefits with the dynamic conformal arcs's simplicity, minimising MLC encroachment while maintaining plan quality. Reduced monitor units lower low-dose exposure, treatment time, and interplay effects. VMATliMU is usable in existing planners with monitor unit limits, offering a practical solution for lung stereotactic body radiation therapy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.