Evidence map›Paper›PMID 40924155›Full record

ArticleArchives of orthopaedic and trauma surgery2025

Estimation of cup orientation on intraoperative fluoroscopy in total hip arthroplasty: how safe is the safe zone-an experimental study.

Roman Maduz, Michel Schläppi, Peter Wahl, Emanuel Benninger, Christoph Meier

Abstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Roman Maduz *Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.
Michel Schläppi *Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland. michel.schlaeppi@ksw.ch.ORCID http://orcid.org/0000-0002-0278-6276
Peter WahlDivision of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.ORCID http://orcid.org/0000-0002-8895-8621
Emanuel BenningerDivision of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.ORCID http://orcid.org/0000-0002-3773-6164
Christoph MeierDivision of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.ORCID http://orcid.org/0000-0001-6944-9648

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAccurate acetabular cup orientation in total hip arthroplasty (THA) is crucial for successful outcomes. Intraoperative fluoroscopy may be used to evaluate acetabular cup placement. This study aimed to evaluate the accuracy of purely visual estimation of cup inclination and anteversion using intraoperative fluoroscopy, considering different surgeon experience levels and cup designs.

methodsThirty-five surgeons with varying levels of experience participated in the study. Standardized fluoroscopic images depicting two different cementless acetabular cup designs placed in a bone model were used. Inclination values ranged from 20 to 60°, while anteversion values ranged from 0 to 40°, both in 5° increments, resulting in 162 combinations of cup orientation. Each participant received a randomly compiled sequence of all images and was provided with instructions for estimating inclination and anteversion angles, and was asked additionally to categorize cup orientations into predefined safe zones, utilizing two definitions: (a) an institutional safe zone (inclination 35 to 45°, anteversion 10 to 20°), and (b) the safe zone according to Lewinnek et al. (inclination 30 to 50°, anteversion 5 to 25°). Participants had no time limit and were not allowed to use measuring tools during the estimation process.

resultsNo significant difference in the precise estimation of inclination and anteversion was found among surgeons of varying experience levels. However, the ability to correctly identify whether cup orientation fell within predefined safe zones improved with surgical experience and seniority. Cup design influenced estimation of inclination, with one design showing superior accuracy. Estimation of anteversion remained consistent across designs. The influence of anteversion on inclination estimation and vice versa was minimal. Safe zone definitions did not significantly affect classification accuracy between cup designs.

conclusionWhile surgical experience did not improve angle estimation accuracy in degrees, it was associated with more accurate identifications of positions within clinically relevant safe zones. Cup design influenced inclination estimation. Our findings emphasize the importance of precise cup positioning in THA and highlight areas for potential improvement in surgical practice and training.

Indexed as

AcetabulumArthroplasty, Replacement, HipHip ProsthesisClinical CompetenceFluoroscopyHumansProsthesis DesignAcetabular cup orientationAnteversionFluoroscopyInclinationSafe zoneTotal hip arthroplasty

Identifiers

PMID40924155
PMCPMC12420742

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.