Evidence map›Paper›PMID 40922922›Full record

ArticleAnnals of gastroenterological surgery2025

Effect of Intraoperative Posture on Accurate Diagnostic Rate of Intraoperative Nerve Monitoring During Esophagectomy.

Masami Yuda, Keita Takahashi, Yoshitaka Ishikawa, Takanori Kurogochi, Akira Matsumoto, Naoko Fukushima, Takahiro Masuda, Naoto Takahashi, Fumiaki Yano, Ken Eto

Abstract read
In one paragraph

Article in Annals of gastroenterological surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Masami YudaDepartment of Gastroenterological Surgery The Jikei University School of Medicine Tokyo Japan.ORCID https://orcid.org/0000-0001-6132-8585
Keita TakahashiDepartment of Gastroenterological Surgery The Jikei University School of Medicine Tokyo Japan.ORCID https://orcid.org/0000-0003-0149-3401
Yoshitaka IshikawaDepartment of Surgery The Jikei University Kashiwa Hospital Chiba Japan.
Takanori KurogochiDepartment of Gastroenterological Surgery The Jikei University School of Medicine Tokyo Japan.
Akira MatsumotoDepartment of Gastroenterological Surgery The Jikei University School of Medicine Tokyo Japan.
Naoko FukushimaDepartment of Gastroenterological Surgery The Jikei University School of Medicine Tokyo Japan.ORCID https://orcid.org/0000-0002-7656-3198
Takahiro MasudaDepartment of Gastroenterological Surgery The Jikei University School of Medicine Tokyo Japan.
Naoto TakahashiDepartment of Surgery The Jikei University Kashiwa Hospital Chiba Japan.
Fumiaki YanoDepartment of Gastroenterological Surgery The Jikei University School of Medicine Tokyo Japan.
Ken EtoDepartment of Gastroenterological Surgery The Jikei University School of Medicine Tokyo Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The benefits of intraoperative nerve monitoring for identifying recurrent laryngeal nerves during esophageal cancer surgery have recently been reported. However, no standardized procedures have been established for the use of this system. This study aimed to identify factors affecting the diagnostic accuracy of intraoperative nerve monitoring for recurrent laryngeal nerve palsy and explore approaches to improve the precision and efficiency of intraoperative nerve monitoring in esophageal cancer surgery. Methods: We analyzed 187 consecutive patients who underwent esophagectomy between 2011 and 2018, of whom 142 underwent intraoperative nerve monitoring. We evaluated factors affecting the diagnostic accuracy of intraoperative nerve monitoring for recurrent laryngeal nerve palsy. Results: The overall incidence of postoperative recurrent laryngeal nerve palsy was 22% (32/142). Univariate analysis identified the left lateral decubitus position (vs. prone position) and not using video laryngoscope during intubation as risk factors for discrepancies between intraoperative nerve monitoring findings and postoperative recurrent laryngeal nerve palsy diagnosis. Multivariate analysis confirmed that the left lateral decubitus position (odds ratio: 4.24; 95% confidence interval: 1.09-13.4, Conclusion: Adequate contact between the intubation tube and vocal cord muscles is crucial for effective intraoperative nerve monitoring during esophagectomy. Additionally, the intraoperative posture significantly affects diagnostic outcomes and should be carefully considered.

Indexed as

esophageal canceresophagectomyintraoperative nerve monitoringintraoperative posturerecurrent laryngeal nerve

Identifiers

PMID40922922
PMCPMC12414599

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.