Evidence map›Paper›PMID 40922890›Full record

ArticleCureus2025

A Novel Posterior Implant System for Sacroiliac Joint Fusion: Preliminary Cadaveric and Clinical Results.

James North, Connor Huxman, Joshua Tandio, Oluwatodimu R Raji, Jeremi M Leasure, Jonathan A Hyde, Andrew Hyde, Thomas P Hedman, Adam Rogers

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

James NorthPain Management, Carolinas Pain Institute, Winston Salem, USA.
Connor HuxmanResearch, Spinal Simplicity, LLC, Overland Park, USA.
Joshua TandioResearch, Medical Device Development, San Francisco, USA.
Oluwatodimu R RajiResearch, Medical Device Development, San Francisco, USA.
Jeremi M LeasureResearch, Medical Device Development, San Francisco, USA.
Jonathan A HydeOrthopaedic and Spinal Surgery, Miami Spine Specialists, Miami Beach, USA.
Andrew HydeMedicine, St. George's University School of Medicine, St. George's, GRD.
Thomas P HedmanResearch, Spinal Simplicity, LLC, Overland Park, USA.
Adam RogersResearch, Spinal Simplicity, LLC, Overland Park, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Sacroiliac joint fusion is performed to stabilize and fuse the joint in patients with degenerative sacroiliitis and joint dysfunction. While several posterior techniques and implants exist as alternatives to lateral approaches, biomechanical and clinical performance data for these systems used as standalone remains limited. This article provides a preliminary cadaveric and clinical assessment of a novel posterior intra-articular sacroiliac fusion implant system. Methods A cadaveric biomechanical evaluation was conducted comparing the posterior implant to a posterolateral transiliac implant, evaluating each device's ability to reduce flexion/extension motion after initial fixation and fatigue loading when used as standalone fixation. Anatomical safety analysis was performed on each implant's post-fixation position, measuring minimum distances to critical SI landmarks on computed tomography (CT) scans. A retrospective clinical evaluation was also conducted, assessing early patient-reported outcomes for patients treated with the posterior device as standalone. Results Biomechanical stability in flexion/extension loading was greater with the posterior implant than the posterolateral implant, both post-fixation (31% motion reduction posterior; 4% increase posterolateral) and after fatigue loading (28% motion reduction posterior; 5% increase posterolateral). Strong effect sizes between implant groups were computed post-fixation (d = 1.92, p = 0.201) and post-fatigue (d = 1.63, p = 0.207), although these differences were not statistically significant with the limited sample size and inter-specimen variability. Compared to the posterolateral implants, the posterior implants were positioned approximately five times further from the sacral foramen (+13.6 mm, p = 0.020) and four times further from the anterior sacral border (+18.5 mm, p = 0.104). Clinical data on 10 patients treated with 13 standalone posterior implants found statistically significant improvements for mean Numerical Rating Scale (NRS) pain scores (4.7 points, 59% improvement, p = 0.014) and Oswestry Disability Index (ODI) scores (10 points, p = 0.029) at an average follow-up of 97 days. All domains of the Patient-Reported Outcomes Measurement Information System (PROMIS-29) assessment also improved (17% mean improvement), with most (4/7) domains showing statistically significant improvement. No device-related adverse events, removals, revisions, or follow-up procedures were reported. Conclusion These preliminary results suggest potential advantages in stability and safety for the novel posterior implant used as a standalone when compared to standalone posterolateral fusion. Early clinical data are promising, showing timely, statistically significant improvements in patient-reported outcomes. Additional biomechanical data and long-term prospective clinical data, including radiographic fusion evaluation, will be necessary to validate these results and further evaluate device performance.

Indexed as

biomechanicsdegenerative sacroiliitisfusion devicepatient-reported outcome measuresposterior intra-articular techniquesacroiliac joint dysfunctionsacroiliac joint fixation