ArticleCureus2025
Suture Repositioning for Subluxation of a Toric-Type Single-Piece Multifocal Intraocular Lens.
Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Haptic-Extended Flange Intrascleral Fixation for Single-Piece Acrylic Intraocular Lenses.Journal of clinical medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intraocular repair for subluxation of a multifocal intraocular lens (MFIOL) can be challenging, especially in toric models. Herein, we report a case of a 43-year-old man with a subluxated toric-type single-piece trifocal intraocular lens (IOL) with a C-loop that was spared using suture repositioning. Pars plana suturing was performed using the haptic externalization technique, and the tram-track suture technique was employed to flatten the tilted toric MFIOL. We also evaluated the postoperative toric axis and IOL position using anterior segment optical coherence tomography (AS-OCT) and a wavefront aberration analyzer. Postoperative AS-OCT revealed a 0.51 mm decentration and 8.7° tilt. The wavefront analysis revealed that the toric axis alignment was <5° from the target axis. The postoperative refractive error and residual astigmatism were minimal; the visual acuity at different distances was acceptable.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.