Evidence map›Paper›PMID 40919258›Full record

ArticleReports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology2025

Evaluation of cubic voxel effects on dose calculation for Iridium-192 high dose rate using TOPAS particle simulation.

Yacine El Attaoui, Zouhair Airouss, Aziz Oustous, Lhoucine Oufni

Abstract read
In one paragraph

Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Commissioning in water of HDR Valencia skin applicators.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yacine El AttaouiLaboratory of Engineering in Chemistry and Physics of Matter (LICPM), Faculty of Sciences and Techniques, Sultan Moulay Slimane University, Beni-Mellal, Morocco.
Zouhair AiroussLaboratory of Engineering in Chemistry and Physics of Matter (LICPM), Faculty of Sciences and Techniques, Sultan Moulay Slimane University, Beni-Mellal, Morocco.
Aziz OustousMoulay Ismail University, Faculty of Sciences, Physical Sciences and Engineering (ENPT), Zitoune, Meknès, Morocco.
Lhoucine OufniLaboratory of Engineering in Chemistry and Physics of Matter (LICPM), Faculty of Sciences and Techniques, Sultan Moulay Slimane University, Beni-Mellal, Morocco.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: This study investigates the impact of voxel size on dose calculations for the FlexiSource iridium-192 ( Materials and methods: TG-43 parameters (radial function and anisotropy function) were calculated using 0.5 mm Results: The measured air-kerma strength per unit source activity differed by 2.34% from consensus data. Radial function analysis showed consistent results, with 0.5 mm Conclusions: These findings validate the TOPAS Monte Carlo code's accuracy for dose calculation and emphasize the importance of voxel size selection. The generated dataset shows promise for future research efforts in brachytherapy dose calculations.

Indexed as

192IrAAPMbrachytherapyCLRPFlexisourceHDRNNDCTG-43TOPAS

Identifiers

PMID40919258
PMCPMC12413219

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.