ArticleInterventional radiology (Higashimatsuyama-shi (Japan)2025
Effect of Coil Type on the Number of Coils Used and the Procedure Time for Pre-Fontan Coil Embolization of Collateral Arteries.
Article in Interventional radiology (Higashimatsuyama-shi (Japan), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: We retrospectively analyzed the effect of coil type on the number of coils used and the procedure time in pre-Fontan coil embolization of collateral arteries. Material and Methods: Twelve patients with congenital heart disease underwent coil embolization before Fontan surgery between 2010 and 2021. They were divided into 2 groups. Group A comprised 6 patients who underwent coil embolization before the introduction of longer microcoils (≥30 cm) and group B comprised 6 patients who underwent embolization after the introduction of the microcoils. The primary endpoints (number of coils used, embolized area per patient and the internal thoracic artery, and procedure time) were compared between the 2 groups. Results: The number of coils used per patient and internal thoracic artery (groups A vs. B: 36.5 vs. 18; p = 0.036, 11.7 vs 7.4; p = 0.047) and the procedure time (247 vs 180 minutes; p = 0.002) were significantly smaller in group B than in group A. The embolized area per internal thoracic artery was significantly larger in group B than in group A (45 vs. 93.5; p < 0.001). All patients underwent Fontan surgery at a mean of 24 days after embolization. Fontan circulation was established in nine of 12 patients. There were no major complications in either group. Conclusions: In pre-Fontan coil embolization, a combination of longer microcoils (≥30 cm) may help reduce the number of coils used and the procedure time, which may decrease the health care cost and radiation exposure.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.