Evidence map›Paper›PMID 40917185›Full record

ArticleHeart rhythm O22025

Differences between 2 cryoballoon systems in achieving successful pulmonary vein isolation in patients with challenging anatomies.

Shuhei Yamashita, Seiji Takatsuki, Shuhei Yano, Yukihiro Himeno, Koki Yamaoka, Susumu Ibe, Yoshinori Katsumata, Takahiko Nishiyama, Takehiro Kimura, Masaki Ieda

Abstract read
In one paragraph

Article in Heart rhythm O2, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Shuhei YamashitaDepartment of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Seiji TakatsukiDepartment of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Shuhei YanoDepartment of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Yukihiro HimenoDepartment of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Koki YamaokaDepartment of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Susumu IbeDepartment of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Yoshinori KatsumataDepartment of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Takahiko NishiyamaDepartment of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Takehiro KimuraDepartment of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Masaki IedaDepartment of Cardiology, Keio University School of Medicine, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: A new technology, the POLAR cryoballoon system, was designed to enhance maneuvering and stabilizing catheter positions with a softer balloon and more deflectable sheath. These novel characteristics may help achieve successful pulmonary vein (PV) isolation in difficult cases when conventional balloons were used. Objective: This study aimed to investigate the differences in the lesion profiles, touch-up radiofrequency ablation (RFA) rate, and anatomical predictors of acute PV isolation between the POLAR and Arctic Front Advance Pro (AFA-Pro). Methods: This retrospective study included 338 consecutive patients who underwent a first cryoballoon ablation for paroxysmal atrial fibrillation at Keio University Hospital from April 2019 to September 2023. Using propensity score matching, we extracted 135 pairs treated with a POLAR or AFA-Pro, compared the procedural outcomes, and explored the anatomical predictors related to successful PV isolations. Results: In the matched cohort of 270 patients (median age 67 years [59-73], 77% male), 1535 cryoballoon applications were delivered for 1063 PVs, and touch-up RFA was performed for 84 PVs in 67 patients. The rate of touch-up RFA was significantly lower for the right inferior PV (RIPV) in the POLAR group (9.8% vs 21.6% Conclusion: The touch-up RFA rate for the RIPV was significantly lower in the POLAR group than in the AFA-Pro group, with a particularly pronounced difference for inferiorly oriented RIPVs.

Indexed as

AnatomyAtrial fibrillationCryoballoon ablationPulmonary vein isolationTouch-up radiofrequency ablation

Identifiers

PMID40917185
PMCPMC12411963

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.