Evidence map›Paper›PMID 40914834›Full record

ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2025

Patient-Specific 3D-Printed Drill Guides for an Ovine Osteochondral Allograft Transplantation Model.

R Peter Suderman, Mark B Hurtig, Marc D Grynpas, Paul R T Kuzyk, Adele Changoor

Abstract read
In one paragraph

Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Patient-Specific 3D-Printed Drill Guides for an Ovine Osteochondral Allograft Transplantation Model.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

R Peter SudermanFaulty of Applied Science and Engineering, University of Toronto, Toronto, Canada.
Mark B HurtigComparative Orthopaedic Research Laboratory, Department of Clinical Studies, University of Guelph, Guelph, Canada.
Marc D GrynpasFaulty of Applied Science and Engineering, University of Toronto, Toronto, Canada.
Paul R T KuzykKierans Janigan Biomechanics Research Program, Lunenfeld-Tanenbaum Research Institute, Sinai Health System, Toronto, Canada.
Adele ChangoorFaulty of Applied Science and Engineering, University of Toronto, Toronto, Canada.ORCID 0000-0002-0175-6227

Funding

This study was supported by a Canada Graduate Research Scholarship (Masters) from the Natural Sciences and Engineering Research Council of Canada and a Grant from MTF Biologics.
6 · The paper itself

Abstract

Proper alignment between donor and recipient cartilage in osteochondral allograft transplantation supports tissue integration and the formation of a stable articulating surface. This study evaluated the use of patient-specific 3D-printed drill guides to improve alignment in an ovine model of osteochondral allograft transplantation when used in place of a free-hand drilling technique. Fourteen female Arcott sheep underwent bilateral osteochondral allograft transplantation. Drill guides were used to transplant 51 grafts (6.5 mm diameter), while the freehand drilling technique was used to transplant 32 grafts. After a 9-month survival time, tissues were harvested. Cross-sectional confocal microscopy images and histological sections were used to quantify height differences between donor and recipient tissues. Grafts transplanted with the drill guides showed significantly reduced (p = 0.0005) height differences between donor and recipient tissues compared to the freehand drilling technique. However, the guide technique was associated with increased osteophyte development (p = 0.0180) and synovial inflammation (p = 0.0451). These findings demonstrate that patient-specific 3D-printed drill guides improve graft alignment in an ovine model of osteochondral allograft transplantation. Methodological improvements are proposed to minimize osteophyte formation and inflammation in future studies.

Indexed as

Bone TransplantationPrinting, Three-DimensionalAllograftsAnimalsCartilage, ArticularFemaleSheepTransplantation, Homologous3D‐printingosteochondral allograftosteochondral drillingovine model

Identifiers

PMID40914834
PMCPMC12604454

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.