Evidence map›Paper›PMID 40908667›Full record

ArticleActa oncologica (Stockholm, Sweden)2025

Comparison of two dual-energy CT-based methods for proton stopping-power ratio estimation in brain cancer patients with metal implants.

Ivanka Sojat Tarp, Vicki Trier Taasti, Maria Fuglsang Jensen, Ludvig Paul Muren, Kenneth Jensen

Abstract readComparative Study
In one paragraph

Article in Acta oncologica (Stockholm, Sweden), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Practical considerations for handling implants in proton therapy.Journal of applied clinical medical physics · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ivanka Sojat TarpDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark. ivatar@rm.dk.ORCID 0009-0007-3421-7565
Vicki Trier TaastiDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.ORCID 0000-0002-4588-9769
Maria Fuglsang JensenDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.
Ludvig Paul MurenDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.ORCID 0000-0002-7418-5832
Kenneth JensenDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.ORCID 0000-0002-2364-965X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeAccurate stopping-power ratio (SPR) estimation is crucial for proton therapy planning. In brain cancer patients with metal clips, SPR accuracy may be affected by high-density materials and imaging artefacts. Dual-energy CT (DECT)-based methods have been shown to improve SPR accuracy. This study evaluated the consistency between two SPR estimation methods in brain cancer patients: (1) a Hounsfield look-up table (HLUT) for DECT-generated virtual monoenergetic images (VMIs) and (2) the DirectSPR algorithm (Siemens Healthineers). Patient/material and methods: DECT scans were acquired for 11 brain cancer patients. Two SPR maps were generated: one using a 90 keV VMI with a HLUT and the other via the DirectSPR algorithm. The VMI HLUT was adjusted in high-density regions to align with the SPR of titanium. Clinically applied proton therapy plans were recalculated on both SPR maps and dose distributions were compared using dose-volume histograms. Furthermore, a voxel-wise SPR comparison and a separate titanium implant analysis were performed.

resultsDose differences between the SPR methods were minimal for organs-at-risk. DirectSPR showed strong SPR agreement with the VMI HLUT approach for CT numbers up to 1500 HU (SPR~1.9). Beyond this, especially in regions with titanium implants, DirectSPR yielded higher SPR values than the VMI HLUT, suggesting an adjustment may also be needed for DirectSPR.

interpretationDirectSPR was consistent with the VMI HLUT up to 1500 HU but deviated at higher CT numbers. These deviations had limited impact on dose metrics, but they should be considered when choosing beam orientations.

Indexed as

Brain NeoplasmsProstheses and ImplantsProton TherapyRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedAlgorithmsHumansMetalsOrgans at RiskRadiotherapy DosageMetals

Identifiers

PMID40908667
PMCPMC12421333

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked