ArticleJAMA network open2025
Design, Conduct, and Analysis of Externally Controlled Trials.
Article in JAMA network open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- External Control Arms in Japan: A Systematic Case Analysis of Documented Regulatory Implementation and Uncertainty Management.Clinical pharmacology and therapeutics · 2026Article
- A New Paradigm for Pediatric AML: Improving the Pipeline for Treatments Targeting Cytogenetic and Molecular Alterations.Cancers · 2026Review
- Review
- Artificial Intelligence as a Disruptive Force in Pharmaceutical Innovation: Transforming Discovery, Development, and Manufacturing.Drug design, development and therapy · 2026Review
- Design, Conduct, and Analysis of Externally Controlled Trials.JAMA network open · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: Externally controlled trials (ECTs) can serve as an alternative in settings where randomized clinical trials (RCTs) are unfeasible. However, the methodological rigor of ECTs, particularly with regard to bias control, is often inadequately assessed, which can compromise the validity of studies and lead to incorrect decisions. Objective: To examine the design, conduct, and analysis characteristics of current ECTs and to assess whether appropriate methods were used to control bias. Design, Setting, and Participants: This cross-sectional study searched PubMed for ECTs published between January 1, 2010, and December 31, 2023. Eligible ECTs included single-arm trials with an external control or that used a treatment group from an RCT compared with an external control and evaluated the efficacy and/or safety of a drug or medical device. Data analysis was conducted from March 5 to 20, 2025. Main Outcomes and Measures: Extracted information included design characteristics, external control data sources, transparency in covariate selection, statistical methods, and the use of sensitivity and quantitative bias analyses. The characteristics of included ECTs were compared between journals in the top 25% in their Journal Citation Reports category (Q1) and non-Q1. Results: This study included 180 ECTs, of which 85 (47.2%) focused on oncology. Only 64 (35.6%) provided reasons for using external controls, and 29 (16.1%) were prespecified to use external controls. The main sources of external controls were clinical (also termed real-world) data (98 [54.4%]) and trial-derived controls (67 [37.2%]), while concurrent data collection with the treatment arm was relatively infrequent (18 [10.0%]). Only 14 studies (7.8%) conducted feasibility assessments to evaluate the adequacy of data sources, and 13 (7.2%) specified how to handle missing data in external control datasets. Covariate selection procedures were described in 37 of the 164 studies (22.6%) that reported important covariates. Sixty studies (33.3%) used statistical methods to adjust for important covariates when generating the external control, with the propensity score method being the most common (35 of 60 [58.3%]). Among 120 ECTs that generated external controls without statistical methods, 91 (75.8%) used univariate analysis to estimate treatment effects, and only 18 (15.0%) used multivariable regression analysis. Sensitivity analyses for primary outcomes were performed in 32 studies (17.8%), and quantitative bias analyses (2 [1.1%]) were nearly absent. ECTs in Q1 journals were more likely to prespecify the use of external controls (χ21 = 9.86; P = .002) and provided rationales for using external controls (χ21 = 4.33; P = .04). Thirteen recommendations for the careful practice of ECTs are proposed. Conclusions and Relevance: In this cross-sectional study of ECTs, current practices in the design, conduct, and analysis were suboptimal, limiting their reliability and credibility. The study identified several critical methodological issues, such as the lack of justification for using external controls, failure to prespecify external controls in the protocol, insufficient use of confounding adjustment techniques, inadequate sensitivity analyses, and almost complete absence of quantitative bias analyses. Therefore, actionable suggestions for future ECT practices are proposed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials