Evidence map›Paper›PMID 40904164›Full record

ArticleMedical physics2025

Software Article: A generalized cascaded linear system model implementation for x-ray detectors.

Gustavo Pacheco, Juan J Pautasso, Koen Michielsen, Ioannis Sechopoulos

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Gustavo PachecoDept. of Medical Imaging, Radboudumc, Nijmegen, The Netherlands.
Juan J PautassoDept. of Medical Imaging, Radboudumc, Nijmegen, The Netherlands.
Koen MichielsenDept. of Medical Imaging, Radboudumc, Nijmegen, The Netherlands.
Ioannis SechopoulosDept. of Medical Imaging, Radboudumc, Nijmegen, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCascaded linear models are widely used for the development and optimization of x-ray imaging systems, yet no publicly available Python implementation currently exists. We introduce CASYMIR, a flexible and open-source Python package capable of modeling direct and indirect-conversion x-ray imaging detectors under various acquisition conditions.

methodsWe employed a modular software design with generalized frequency-domain expressions for each process in the detection chain, which can be implemented as serial or parallel blocks. The gain factors and other parameters are derived from the detector's characteristics, system geometry, and incident x-ray spectra, all of which can be specified by the user. The signal reaching the detector is propagated throughout the detection stages by applying these process blocks, enabling the computation of the Modulation Transfer Function (MTF) and Noise Power Spectrum (NPS) at any stage of the model. VALIDATION: Our implementation was experimentally validated using two commercial x-ray detectors: a flat-panel a-Se detector for digital mammography and digital breast tomosynthesis, and a flat-panel scintillator (CsI) detector for dedicated breast CT. The modeled MTF had root-mean-square (RMS) percent errors below 6% for the a-Se detector, while the normalized RMS error for the NNPS was below 3%. For the CsI detector, the RMS percent error in the MTF was 5.4%, and the normalized RMS error for the NNPS was 5.8%. USAGE NOTES: The CASYMIR Python package can be downloaded from https://github.com/radboud-axti/casymir_public, and it includes a standalone executable script suitable for modeling common commercial systems, along with an extensive README file and example files. POTENTIAL APPLICATIONS: CASYMIR is available as an open-source Python package under the MIT license. Given its modular and flexible structure, it can be easily modified and integrated into other simulation/virtual clinical trial pipelines where information about the detector's spatial resolution and noise performance is needed. The standalone version of CASYMIR may be particularly useful for running batch simulations with varying acquisition and system parameters, making it ideal for optimizing system design and acquisition techniques. Furthermore, given the package's modular structure, new processes can be implemented to simulate other detector and system designs.

Indexed as

SoftwareLinear ModelsMammographyX-Raysflat‐panel detectorimage qualityparallel cascaded modelsX‐ray detectors

Identifiers

PMID40904164
PMCPMC12409217

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.