Evidence map›Paper›PMID 40898001›Full record

ArticleCardiovascular engineering and technology2025

A Simulation-Based Comparison of Human, Porcine and Ovine Pulmonary Artery Hemodynamics. Evaluating the Suitability of Large Animal Models for Endopulmonary Device Evaluation from a Hemodynamics Point of View.

Pavlo Yevtushenko, Titus Kuehne, Jan Bruening, Leonid Goubergrits

Abstract readComparative Study
In one paragraph

Article in Cardiovascular engineering and technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Pavlo YevtushenkoInstitute of Computer-assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany. pavlo.yevtushenko@dhzc-charite.de.ORCID 0000-0003-0796-8922
Titus KuehneInstitute of Computer-assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany.
Jan BrueningInstitute of Computer-assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany.
Leonid GoubergritsInstitute of Computer-assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany.

Funding

EUROPEAN UNION 101017578
6 · The paper itself

Abstract

In the field of cardiovascular device development, new devices such as heart valves, stents or pressure probes for long term heart failure monitoring are subject to animal trials to evaluate their safety and efficacy. For such applications, swine and sheep are the animal models of choice owed to their similarities to humans with regards to heart size, weight and ventricular kinetics. However, clinical aspects regarding the choice of animal model revolve mainly around anatomical similarities as well as the ability to induce the desired pathology. In the case of pulmonary artery pressure sensors, both swine and sheep appear to be suitable candidates for animal trials since both animals have been used for pre-clinical evaluation. Hemodynamic aspects however, although equally important for device performance, appear rather underrepresented in current research and it remains uncertain whether anatomical similarities between humans and animal model in the region of interest translate to hemodynamic similarities. To provide insight whether pulmonary artery hemodynamics in large animal models are indeed comparable to those in humans, this work presents a computational fluid dynamics-based study on pulmonary artery hemodynamics for humans, swine and sheep. A total of 28 human, 41 porcine and 14 ovine transient simulations of pulmonary artery hemodynamics were performed based on subject-specific geometries reconstructed from computed tomography data. The distributions of wall shear stress (WSS) and oscillatory shear index (OSI) within the cohorts were then compared to assess hemodynamic similarity. Distributions of time averaged WSS were found to be similar between humans and sheep (median 1.2 vs. 1.5 Pa, interquartile range (IQR) 0.8 Pa vs. 0.6 Pa, Wilcoxon rank sum test p = 0.42) but were significantly different for swine (median 1.7, IQR 0.5, p < 0.05), whereas OSI was significantly different for sheep and swine (0.17 ± 0.04 vs. 0.14 ± 0.03 and 0.09 ± 0.02). between sheep and humans. In summary, pulmonary artery vessel wall stresses of both animal models appear broadly similar to humans, however, sheep seem to have a notable edge over swine in our study.

Indexed as

Computer SimulationHemodynamicsModels, CardiovascularPulmonary ArteryAnimalsHumansModels, AnimalSheepSpecies SpecificitySwineComputational fluid dynamicsComputed tomographyOscillatory shear indexPulmonary artery pressure sensorWall shear stress

Identifiers

PMID40898001
PMCPMC12686054

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked