Evidence map›Paper›PMID 40897716›Full record

ArticleNature communications2025

Fully biocompatible, thermally drawn fiber supercapacitors for long-term bio-implantation.

Sungha Jeon, Hyeonyeob Seo, Yeji Kim, Youngin Choi, Youngbin Lee, Youngmin Jung, Somin Lee, Jung Tae Lee, Seongjun Park

Abstract read
In one paragraph

Article in Nature communications, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. From Devices to Systems: Integration Strategies for Micro-Supercapacitors in Microsystems.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  3. Materials and System Design for Self-Decision Bioelectronic Systems.Advanced materials (Deerfield Beach, Fla.) · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Sungha Jeon *Medical Research Center, Seoul National University, Seoul, Republic of Korea.
Hyeonyeob Seo *Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea.ORCID http://orcid.org/0000-0002-8297-4743
Yeji Kim *Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea.ORCID http://orcid.org/0000-0002-5423-5994
Youngin ChoiDepartment of Biomedical Sciences, Graduate School of Biomedical Science and Engineering, Hanyang University, Seoul, Republic of Korea.
Youngbin LeeMedical Research Center, Seoul National University, Seoul, Republic of Korea.
Youngmin JungSchool of Transdisciplinary Studies, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea.
Somin LeeProgram of Brain and Cognitive Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea.
Jung Tae LeeDepartment of Plant and Environmental New Resources, Kyung Hee University, Yongin-si, Gyeonggi-do, Republic of Korea. jungtae@khu.ac.kr.ORCID http://orcid.org/0000-0002-2228-1849
Seongjun ParkMedical Research Center, Seoul National University, Seoul, Republic of Korea. seongjunpark@snu.ac.kr.ORCID http://orcid.org/0000-0002-1981-9628

Funding

National Research Foundation of Korea (NRF) RS-2023-00207970National Research Foundation of Korea (NRF) RS-2023-00225427National Research Foundation of Korea (NRF) RS-2024-00403009
6 · The paper itself

Abstract

Recent advancements in implantable bioelectronic devices have increased the demand for biocompatible energy sources with long-term electrochemical and mechanical stability. Here, we present a tough hydrogel-based supercapacitor (THBS) fiber, fabricated via a thermal drawing process (TDP), that enables the integration of all components-electrodes, electrolyte, current collectors, and encapsulation-into a single, unified, and mechanically robust fiber-shaped architecture. Through thermal/mechanical optimization and the incorporation of self-healing properties, THBS fibers exhibit durable, high electrochemical performance under dynamic, high-curvature deformations mimicking in vivo physiological motions. Despite a thickness of only a few hundred microns, they maintain mechanical and electrochemical stability. Long-term functionality was confirmed over five weeks with minimal immune response. In vivo implantation demonstrated successful LED operation in a freely moving mouse, and successful optogenetic stimulation of both central and peripheral nervous systems. These results underscore the promise of THBS fibers as next-generation, fully biocompatible energy storage devices for advanced implantable bioelectronic systems.

Indexed as

Biocompatible MaterialsProstheses and ImplantsAnimalsElectric CapacitanceHydrogelsMiceOptogeneticsBiocompatible MaterialsHydrogels

Identifiers

PMID40897716
PMCPMC12405512

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked