Evidence map›Paper›PMID 40896030›Full record

ArticleCureus2025

Effect of Soft Tissue Thickness on Crestal Bone Levels and Implant Stability With Platform-Switched Abutments: A Prospective Study.

Morupuri Sunitha, Thota K Mohan, Gottumukkala Vineela, Naga Sai Aneesha, Navya K Chowdary, Kura Srikanth

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Morupuri SunithaDepartment of Prosthodontics, Sibar Institute of Dental Sciences, Guntur, IND.
Thota K MohanDepartment of Prosthodontics, Sibar Institute of Dental Sciences, Guntur, IND.
Gottumukkala VineelaDepartment of Prosthodontics, Sibar Institute of Dental Sciences, Guntur, IND.
Naga Sai AneeshaDepartment of Prosthodontics, Sibar Institute of Dental Sciences, Guntur, IND.
Navya K ChowdaryDepartment of Prosthodontics, Sibar Institute of Dental Sciences, Guntur, IND.
Kura SrikanthDepartment of Periodontics, Meghna Institute of Dental Sciences, Nizamabad, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionSoft tissue thickness may play a role in the success of dental implants by influencing factors such as bone health and implant stability. This study aimed to evaluate the effect of mucosal thickness on crestal bone levels and implant stability in patients with platform-switched abutments. The objectives were to measure bleeding on probing (BOP), implant stability, and changes in crestal bone levels in thin and thick mucosal environments over six months post-prosthetic loading. MATERIALS AND

methodsThis prospective study included 20 partially edentulous patients divided into two groups: Group 1 (thin mucosa, <1 mm) and Group 2 (thick mucosa, 1-2 mm). Mucosal thickness was measured using a Mani K-file no. 20 (Mani, Utsunomiya, Japan). Two-piece titanium implants (3.7 mm diameter, 10 mm length, Alpha Bio, Petah Tikva, Israel) were placed using a surgical stent and sequential drilling with a physiodispenser (W&H, Bürmoos, Austria). Implant stability was assessed by resonance frequency analysis using an Osstell device (Osstell AB, Göteborg, Sweden). Crestal bone levels were measured using intraoral periapical radiographs with an X-ray grid. Platform-switched (PS) abutments were placed at three months, followed by screw-retained metal ceramic crowns. Clinical parameters (BOP, mucosal thickness, implant stability, and crestal bone levels) were evaluated at baseline, three months during the second surgery, and six months post-prosthetic loading. Data were analyzed using parametric and nonparametric tests with significance set at p < 0.05.

resultsThe thick mucosa group exhibited significantly less crestal bone loss and higher implant stability at six months than the thin mucosa group (p < 0.05). BOP was absent in both groups of patients. Mucosal thickness remained stable, with significant differences between groups at all time points (p = 0.001). Implant stability improved over time in both groups (p = 0.001).

conclusionPS abutments promoted favorable peri-implant outcomes, with thicker mucosa associated with reduced crestal bone loss and enhanced stability, highlighting the role of mucosal thickness in optimizing implant success.

Indexed as

bone lossdental implantmucosaplatform switchingsoft tissue

Identifiers

PMID40896030
PMCPMC12393306

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.