Evidence map›Paper›PMID 40895850›Full record

ArticleCureus2025

Reliability of Point-of-Care Venous Blood Gas Testing for Potassium and Sodium Compared to Central Laboratory Results in Emergency Patients: A Clinical Audit.

Chafika Lasfer, Amal Lahib, Kariem Soliman, Shahinaz Gouda

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Chafika LasferEmergency Medicine, Fakeeh University Hospital, Dubai, ARE.
Amal LahibEmergency Medicine, Fakeeh University Hospital, Dubai, ARE.
Kariem SolimanEmergency Medicine, Fakeeh University Hospital, Dubai, ARE.
Shahinaz GoudaEmergency Medicine, Fakeeh University Hospital, Dubai, ARE.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Point-of-care testing (POCT) is widely employed in emergency departments (EDs) for rapid clinical decision-making. However, the reliability of POCT for assessing critical electrolytes like potassium (K⁺) and sodium (Na⁺), compared to central laboratory methods, remains under scrutiny. Objective This quality improvement (QI) study aimed to evaluate and improve the reliability of POC venous blood gas (VBG) testing for K⁺ and Na⁺ by comparing results with central laboratory values. Structured within a Plan-Do-Study-Act (PDSA) cycle, the objectives included quantifying the analytical concordance using Pearson correlation and Bland-Altman methods, identifying systematic bias or clinical outliers, and assessing turnaround time (TAT) to inform iterative improvements in POCT protocol integration within the ED. Methods A retrospective audit was conducted on 120 patients (N = 120, 100%) at Fakeeh University Hospital, Dubai, from March to May 2023. Paired K⁺ and Na⁺ values from POCT VBG analyzers and laboratory reports were compared. Statistical analysis included scatter plots, Pearson correlation, and Bland-Altman agreement. Results Of the 120 patients, 65 (54.2%) were male and 55 (45.8%) were female, with a mean age of 47.3 years (SD = 16.1). Chief presentations included chest pain (N = 38, 31.7%), dyspnea (N = 32, 26.7%), vomiting (N = 23, 19.2%), and signs of dehydration (N = 27, 22.5%). POCT K⁺ and Na⁺ values showed strong correlation with laboratory values (r = 0.91 and r = 0.88, respectively). The mean bias for K⁺ was +0.12 mmol/L, and for Na⁺ it was -1.2 mmol/L. TAT was significantly shorter for POCT (mean = 2.4 minutes) versus laboratory results (mean = 12.3 minutes), with a median delay of 10 minutes. Conclusion POCT demonstrated high reliability for K⁺ and Na⁺ evaluation in EDs. However, caution is advised when interpreting extreme values, especially hyperkalemia (> 5.5 mmol/L). Central laboratory confirmation should be considered in borderline or critical cases.

Indexed as

diagnostic accuracyelectrolyte monitoringemergency medicinepoint-of-care testing (poct)venous blood gas (vbg)

Identifiers

PMID40895850
PMCPMC12397831

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.