Evidence map›Paper›PMID 40895766›Full record

ArticleAPL bioengineering2025

A fully implantable sensorized artificial urinary bladder to restore continence and fullness monitoring.

F Semproni, V Iacovacci, S Musco, S Onorati, M Ibrahimi, A Menciassi

Abstract read
In one paragraph

Article in APL bioengineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

F SemproniThe BioRobotics Institute and Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy.ORCID https://orcid.org/0000-0001-7913-1094
V IacovacciThe BioRobotics Institute and Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy.ORCID https://orcid.org/0000-0002-4052-3581
S MuscoNeuro- Urology Department, Azienda Ospedaliero Universitaria Careggi, Florence, Italy.ORCID https://orcid.org/0000-0001-5844-5684
S OnoratiThe BioRobotics Institute and Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy.ORCID https://orcid.org/0000-0002-7142-5896
M IbrahimiThe BioRobotics Institute and Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy.ORCID https://orcid.org/0000-0001-9764-9014
A MenciassiThe BioRobotics Institute and Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy.ORCID https://orcid.org/0000-0001-6348-1081

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A fully implantable sensorized organ to replace the natural urinary bladder holds considerable promise for patients undergoing radical cystectomy. Clinical options to restore continence include urine redirection to wearable bags or reconstruction of neobladders from autologous tissues, often with limited capacity. However, none of these approaches can restore patient's ability to perceive bladder fullness, making voiding self-management complex and burdensome. To address these limitations, we introduce the Soft Self-Sensitive Artificial Bladder (S3AB), a fully implantable sensorized organ designed to replace urinary bladder anatomy, as well as continence and fullness monitoring. The S3AB main component is a silicone origami-inspired bladder designed to fit the abdominopelvic cavity. The foldable and soft nature facilitates the maintenance of intravesical pressure below the physiological range, thereby promoting the preservation of renal function over time. The bladder is integrated with a multi-sensor system based on resistive textile sensors featuring durability and functionality throughout repetitive cycles of filling and draining. The sensors demonstrate stability at physiological temperatures. Once isolated from bodily fluids, textile sensors permit to monitor the bladder internal volume leveraging on the origami structure opening during filling, with an estimation accuracy within approximately 12%. Volume monitoring allows warning the patient when the maximum capacity is almost reached, thus making possible a natural micturition management. S3AB proved efficient in restoring urine collection and filling state monitoring upon successful implantation in a large animal model.

Identifiers

PMID40895766
PMCPMC12396846

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.