ArticleArXiv2025
Multimodal concentric surface coils for enhanced sensitivity in MR imaging.
Article in ArXiv, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Updated by
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study presents the design, simulation, and experimental validation of a novel multimodal concentric surface coil for MR imaging, developed to achieve higher B1 field efficiency while maintaining low SAR for enhanced imaging performance. The coil comprises multiple electromagnetically coupled concentric resonators of varying sizes. The resonant frequency of a desired mode is tuned to 127 MHz, as an example, to demonstrate the performance of the proposed technique at 3 Tesla. Fullwave electromagnetic simulations of the proposed design and bench tests of fabricated prototypes were conducted to evaluate the coil's B1 field efficiency and distribution, multimodal resonance behavior, scattering parameters, and SAR performance. Inductive Current Elimination or magnetic wall decoupling was implemented to enhance channel isolation in a multi channel configuration to demonstrate the feasibility of applying this multimodal technique to RF array design and parallel imaging. Experimental results show that the proposed concentric coil achieves higher B1 field efficiency and reduced SAR compared to a conventional surface coil of the same size operating at 3 Tesla. Bench measurements on the prototypes confirmed successful tuning and impedance matching, with measured S11 and S21 parameters validating the effectiveness of the decoupling strategy. B1 mapping experiments further demonstrated efficient RF power delivery across multiple planes. These findings suggest that the proposed multimodal concentric coil has the potential to serve as a promising alternative to conventional surface coils for high performance MR imaging, offering enhanced RF efficiency, reduced SAR, and the ability to construct multichannel RF arrays.
Identifiers
40895084PMC12393240What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.