Evidence map›Paper›PMID 40894375›Full record

ArticleStructural heart : the journal of the Heart Team2025

Improving Efficiency in Performing Transcatheter Aortic Valve Replacement Procedure: Experience With 1000 TAVR Procedures.

Mohammed Quader, Neha Shah, Rebecca Deitch, Barbara Lawson, Delia Endicott, Zachary Gertz

Abstract read
In one paragraph

Article in Structural heart : the journal of the Heart Team, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mohammed QuaderDivision of Cardiothoracic Surgery, Department of Surgery, Virginia Commonwealth University, Richmond, Virginia.
Neha ShahDivision of Cardiothoracic Surgery, Department of Surgery, Virginia Commonwealth University, Richmond, Virginia.
Rebecca DeitchDivision of Cardiothoracic Surgery, Department of Surgery, Virginia Commonwealth University, Richmond, Virginia.
Barbara LawsonPauley Heart Center, Virginia Commonwealth University Health, Richmond, Virginia.
Delia EndicottPauley Heart Center, Virginia Commonwealth University Health, Richmond, Virginia.
Zachary GertzPauley Heart Center, Virginia Commonwealth University Health, Richmond, Virginia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Since Food and Drug Administration approval of transcatheter aortic valve replacement (TAVR) in 2011, advancements in technology and procedural refinements have improved efficiency and safety. By systematically eliminating steps in the original TAVR protocol, we achieved reductions in procedural time, contrast volume, and fluoroscopy time without compromising outcomes. Methods: Institutional TAVR data (November 2012 to September 2023) were analyzed, focusing on procedural times, contrast volume, radiation exposure, and outcomes. Four protocol modifications were compared: traditional protocol (2012 to 2016), elimination of rotational angiogram (2017 to 2020), elimination of balloon valvuloplasty (2020 to 2022), and elimination of femoral angiogram (2022 to 2023). Results: Among 1095 TAVR procedures, 88.5% were femoral access, and 86.0% were done under conscious sedation. The mean age of patients was 79.0 ± 8.7 years, with 59% males. Most patients were classified in the Society of Thoracic Surgeons intermediate-risk category (38.4%), followed by prohibitive risk (30.0%), high risk (23.9%), and low risk (7.4%). Average procedural time, contrast volume, and fluoroscopy time were 88.4 ± 38.0 ​minutes, 73.0 ± 38.8 mL, and 13.8 ± 7.9 ​minutes, respectively. Adverse events occurred in 15%, with vascular complications (3.7%) being the most common. Mortality was 1.5%, highest in transapical (15%) and lowest in femoral (0.3%). Protocol modifications were associated with significant reductions in procedural time (59.99 ± 15.2 vs. 97.8 ± 33.9 ​minutes), contrast use (40.1 ± 26.6 vs. 92.9 ± 38.1 mL), fluoroscopy time (8.6 ± 7.4 vs. 18.5 ± 8.5 ​minutes), and complications (5.5 vs. 25.6%), all Conclusions: Systematic elimination of procedural steps was associated with reduced procedural time, contrast use, and fluoroscopy time, without compromising patient safety. These refinements may enhance procedural efficiency and patient outcomes.

Indexed as

Aortic valve stenosisEfficiencyTranscatheter aortic valve replacement

Identifiers

PMID40894375
PMCPMC12399234

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.