Evidence map›Paper›PMID 40894363›Full record

ArticleStructural heart : the journal of the Heart Team2025

Outcomes of Patients With a Small and Large Aortic Annulus Following Balloon-Expandable Transcatheter Aortic Valve Replacement Across Flow-Gradient Patterns.

Besir Besir, Shivabalan Kathavarayan Ramu, Tamari Lomaia, Maryam Muhammad Ali Majeed-Saidan, Judah Rajendran, Issam Motairek, Serge C Harb, Rhonda Miyasaka, Grant W Reed, Rishi Puri and 3 more

Abstract read
In one paragraph

Article in Structural heart : the journal of the Heart Team, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Besir BesirDepartment of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Shivabalan Kathavarayan RamuDepartment of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Tamari LomaiaDepartment of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Maryam Muhammad Ali Majeed-SaidanDepartment of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Judah RajendranDepartment of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Issam MotairekDepartment of Internal Medicine, Cleveland Clinic, Cleveland, Ohio, USA.
Serge C HarbSection of Cardiovascular Imaging, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.
Rhonda MiyasakaSection of Cardiovascular Imaging, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.
Grant W ReedDepartment of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Rishi PuriDepartment of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
James J Y YunDepartment of Thoracic and Cardiovascular Surgery, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Amar KrishnaswamyDepartment of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Samir R KapadiaDepartment of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Patients with small annuli are at risk for worse hemodynamic performance after transcatheter aortic valve replacement (TAVR). It is debatable whether a small annulus confers worse outcomes. This study explored the clinical outcomes following TAVR for patients with small and large annuli across flow-gradient subgroups of aortic stenosis (AS). Methods: This is a retrospective cohort of patients >18 years who underwent TAVR at Cleveland Clinic between 2016 and 2020. Patients were classified into 2 groups according to annular size: small (area ≤430 mm Results: The study included 1866 patients, of which 709 (38%) had small annuli. There was no difference in heart failure rehospitalization and mortality between the groups in any of the 4 flow-gradient patterns: hazard ratio (HR) ​= ​0.93 (95% confidence interval [CI]: 0.51-1.69) for patients with classical LFLG AS, HR ​= ​0.95, CI (0.62-1.47) for patients with paradoxical LFLG AS, HR = ​1.16, CI (0.49-2.74) for patients with normal-flow low-gradient AS, and HR = ​0.73, CI (0.50-1.07) for patients with high-gradient AS, using large annulus as a reference. Patients with small annuli had higher mean gradients, lower dimensionless valve index, and a higher incidence of hypoattenuated leaflet thickening and structural valve deterioration post-TAVR. Conclusions: Patients with small and large annuli have similar intermediate-term clinical outcomes post-TAVR across all flow-gradient patterns treated with balloon-expandable valve.

Indexed as

Aortic stenosisBalloon-expandable valveHigh-gradientLow-gradientSmall annulusTranscatheter aortic valve replacement (TAVR)

Identifiers

PMID40894363
PMCPMC12399270

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked