Evidence map›Paper›PMID 40893538›Full record

ArticleQuantitative imaging in medicine and surgery2025

Novel RANSAC-based method for detecting and estimating externally attached marker spheres in craniomaxillofacial CT images.

Yonghui Li, Han Zhang, Weili Shi, Wei He, Yu Miao, Guodong Wei, Zhengang Jiang

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yonghui LiSchool of Computer Science and Technology, Changchun University of Science and Technology, Changchun, China.
Han ZhangJilin Provincial Key Laboratory of Tooth Development and Bone Remodeling, School and Hospital of Stomatology, Jilin University, Changchun, China.
Weili ShiSchool of Computer Science and Technology, Changchun University of Science and Technology, Changchun, China.
Wei HeSchool of Computer Science and Technology, Changchun University of Science and Technology, Changchun, China.
Yu MiaoSchool of Computer Science and Technology, Changchun University of Science and Technology, Changchun, China.
Guodong WeiSchool of Computer Science and Technology, Changchun University of Science and Technology, Changchun, China.
Zhengang JiangSchool of Computer Science and Technology, Changchun University of Science and Technology, Changchun, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The precision of image-physical space registration using spherical markers in craniomaxillofacial surgical navigation significantly depends on the accurate estimation of spherical parameters from computed tomography (CT) images. However, this estimation is susceptible to the abnormal points caused by artifacts, instruments interference, and other factors. To address these challenges, this study proposes a robust method to improve reproducibility in results and achieve higher accuracy on low inlier ratio data, thereby meeting the requirements of high-precision surgical applications. Methods: Firstly, potential marker sphere regions are isolated from CT images. Next, we propose the Local Evaluation and Optimization RANdom SAmple Consensus (LEO-RANSAC) algorithm to refine the detection of the spherical parameters. This technique introduces a metric that combines multi-level adaptive curvature and local solution to filter local models, and adopts an equidistance adjustment mechanism to improve the accuracy of the so-far-the-best model. Lastly, a custom-designed equipment is utilized to measure the fiducial localization error (FLE), and a skull phantom study is utilized to evaluate the fiducial registration error (FRE) and the target registration error (TRE). Results: The proposed method was evaluated on 72-point clouds with inlier ratio ranging from 30% to 90%. After repeating 100 independent experiments, the deviations of the maximum of FLEs for six different configurations were 0.40±0.25, 0.52±0.35, 0.58±0.35, 0.53±0.25, 0.51±0.28, and 0.39±0.31 mm, respectively. Analysis of 72 results showed that 87.50% of the maximum of FLEs were less than 0.9 mm, and 95.83% of the variances of FLEs were less than 0.01. In a skull phantom study involving 3 different datasets, the FREs were 0.4222, 0.5223, and 0.372 mm, respectively, whereas the TREs were 0.8546, 0.9471, and 0.8537 mm during real-time guidance, respectively. Conclusions: The results demonstrate that our method outperforms existing approaches in terms of accuracy and reliability, highlighting its potential applicability in craniomaxillofacial surgical navigation.

Indexed as

image-physical space registrationRANdom SAmple Consensus (RANSAC)spherical parameter estimationspherical target detectionSurgical navigation

Identifiers

PMID40893538
PMCPMC12397674

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.