ArticleQuantitative imaging in medicine and surgery2025

Minimizing radiation dose in coronary CT angiography using dual single-cardiac phase acquisition with a whole-heart motion correction technology: a prospective randomized study on image quality.

Xin Fang, Shuang Li, Ping Xie, Huanrui Hu, Wenyu Ting, Yongchun You, Jianying Li, Kaiyue Diao, Wanjiang Li

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Xin Fang *Department of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Shuang Li *Department of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Ping XieDepartment of Radiology, Meishan City People Hospital, Meishan, China.
Huanrui HuDivision of Vascular Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, China.
Wenyu TingDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Yongchun YouDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Jianying LiCT Research Center, GE Healthcare, Beijing, China.
Kaiyue DiaoDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Wanjiang LiDepartment of Radiology, West China Hospital, Sichuan University, Chengdu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Coronary computed tomography angiography (CCTA) plays an increasingly important role in coronary artery disease (CAD) evaluation, but radiation dose remains a clinical concern. Conventional multi-cardiac phase (CMP) scanning covers wide R-R intervals to ensure optimal image quality, leading to higher radiation exposure. Recent advances in motion correction technology, particularly whole-heart motion correction algorithms, offer potential solutions for dose reduction. This study aimed to evaluate the feasibility of using dual single-cardiac phase (DSP) acquisition (end-systole: 45% R-R interval and end-diastole: 75% R-R interval) in CCTA with a whole-heart motion correction (SnapShot Freeze 2, SSF2) technology to minimize radiation dose and maintain image quality in comparison with CMP scanning. Methods: In this prospective randomized study, 140 patients were randomly assigned to either DSP (n=70) or CMP (n=70) scanning groups. All examinations were performed on a 256-row wide-detector computed tomography (CT) scanner with similar data acquisition parameters and reconstruction algorithms except cardiac phase range selections. Image quality was assessed both objectively [signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)] and subjectively (5-point scale). Image quality, diagnostic confidence, and acceptability between the two groups and across different heart rates were evaluated. Results: DSP scanning achieved 29% radiation dose reduction [volume CT dose index (CTDIvol): 19.24±4.59 Conclusions: DSP scanning with SSF2 technology achieves significant radiation dose reduction while maintaining comparable image quality to CMP, with 100% diagnostic acceptability when both phases are available.

Indexed as

coronary computed tomography angiography (CCTA)heart rateimage enhancementradiation dosageSnapShot Freeze 2 (SSF2)

Identifiers

PMID40893537
PMCPMC12397654

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.