ArticleQuantitative imaging in medicine and surgery2025
Impact of a deep learning image reconstruction algorithm on the robustness of abdominal computed tomography radiomics features using standard and low radiation doses.
Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Transferability of radiomics models between deep learning and conventional CT reconstruction algorithms: A task-based assessment for stratifying acute pancreatitis severity.Journal of applied clinical medical physics · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Deep learning image reconstruction (DLIR) can enhance image quality and lower image dose, yet its impact on radiomics features (RFs) remains unclear. This study aimed to compare the effects of DLIR and conventional adaptive statistical iterative reconstruction-Veo (ASIR-V) algorithms on the robustness of RFs using standard and low-dose abdominal clinical computed tomography (CT) scans. Methods: A total of 54 patients with hepatic masses who underwent abdominal contrast-enhanced CT scans were retrospectively analyzed. The raw data of standard dose in the venous phase and low dose in the delayed phase were reconstructed using five reconstruction settings, including ASIR-V at 30% (ASIR-V30%) and 70% (ASIR-V70%) levels, and DLIR at low (DLIR-L), medium (DLIR-M), and high (DLIR-H) levels. The PyRadiomics platform was used for the extraction of RFs in 18 regions of interest (ROIs) in different organs or tissues. The consistency of RFs among different algorithms and different strength levels was tested by coefficient of variation (CV) and quartile coefficient of dispersion (QCD). The consistency of RFs among different strength levels of the same algorithm and clinically comparable levels across algorithms was evaluated by intraclass correlation coefficient (ICC). Robust features were identified by Kruskal-Wallis and Mann-Whitney Results: Among the five reconstruction methods, the mean CV and QCD in the standard-dose group were 0.364 and 0.213, respectively, and the corresponding values were 0.444 and 0.245 in the low-dose group. The mean ICC values between ASIR-V 30% and 70%, DLIR-L and M, DLIR-M and H, DLIR-L and H, ASIR-V30% and DLIR-M, and ASIR-V70% and DLIR-H were 0.672, 0.734, 0.756, 0.629, 0.724, and 0.651, respectively, in the standard-dose group, and the corresponding values were 0.500, 0.567, 0.700, 0.474, 0.499, and 0.650 in the low-dose group. The ICC values between DLIR-M and H under low-dose conditions were even higher than those of ASIR-V30% and -V70% under standard dose conditions. Among the five reconstruction settings, averages of 14.0% (117/837) and 10.3% (86/837) of RFs across 18 ROIs exhibited robustness under standard-dose and low-dose conditions, respectively. Some 23.1% (193/837) of RFs demonstrated robustness between the low-dose DLIR-M and H groups, which was higher than the 21.0% (176/837) observed in the standard-dose ASIR-V30% and -V70% groups. Conclusions: Most of the RFs lacked reproducibility across algorithms and energy levels. However, DLIR at medium (M) and high (H) levels significantly improved RFs consistency and robustness, even at reduced doses.