Evidence map›Paper›PMID 40892080›Full record

ArticleClinical oral investigations2025

Effect of different light-curing modes and curing times on degree of conversion and microhardness of three different bulk-fill composites: an in vitro study.

Faiza Javed, Rajendra Kumar Tewari, Sharique Alam, Shahid Husain, Faisal Hasan

Erratum issuedAbstract readComparative Study
PubMed Publisher
In one paragraph

Article in Clinical oral investigations, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Faiza JavedDepartment of Conservative Dentistry and Endodontics, Dr. Ziauddin Ahmad Dental College and Hospital, Aligarh Muslim University, Aligarh, Uttar Pradesh, India.ORCID http://orcid.org/0009-0004-2502-8963
Rajendra Kumar TewariDepartment of Conservative Dentistry and Endodontics, Dr. Ziauddin Ahmad Dental College and Hospital, Aligarh Muslim University, Aligarh, Uttar Pradesh, India.ORCID http://orcid.org/0000-0002-6116-5592
Sharique AlamDepartment of Conservative Dentistry and Endodontics, Dr. Ziauddin Ahmad Dental College and Hospital, Aligarh Muslim University, Aligarh, Uttar Pradesh, India. Sharique2004@gmail.com.ORCID http://orcid.org/0000-0002-4917-3880
Shahid HusainDepartment of Physics, Aligarh Muslim University, Aligarh, Uttar Pradesh, India.ORCID http://orcid.org/0000-0001-9145-0020
Faisal HasanDepartment of Mechanical Engineering, Zakir Husain College of Engineering and Technology, Aligarh Muslim University, Aligarh, Uttar Pradesh, India.ORCID http://orcid.org/0000-0002-9901-890X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis in vitro study aims to compare the effect of different light curing modes and curing times on the degree of conversion (DC) and microhardness (MH) of three different bulk fill composites at two different depths. MATERIALS AND

methodsA total of 224 cylindrical specimens (4 mm height, 6 mm diameter) were prepared using four composites: SDR Plus, Ever X Posterior (EXP), Beautifil Bulk Restorative (BBR), and Tetric N Ceram (TNC). Each material group (n = 56) was subdivided into four curing subgroups based on light-curing mode (Low Power or High Power) and exposure time (20-30 s). Following curing, all samples were stored at 37 °C for 24 h. From each subgroup, seven specimens were allocated for DC testing using Raman spectroscopy and seven for MH testing using the Vickers microhardness test.

resultsAll the materials achieved acceptable (> 80%) bottom-to-top Vickers hardness ratio in high power (HP) mode for both curing times. However, in the low power (LP) mode, EXP could not achieve this ratio at 20 s and BBR failed to achieve this ratio in both curing times. BBR could not achieve an acceptable DC (> 55%) in both curing modes and both curing times. EXP did not demonstrate acceptable DC in LP mode at 20 s curing time, while SDR showed acceptable DC in both curing modes and both curing times.

conclusionCompliance with manufacturers' instructions yielded acceptable outcomes in most cases. Each bulk fill material has different requirements pertaining to curing intensity and time to achieve desirable microhardness and degree of conversion. Clinicians should be aware of the curing protocol for the specific bulk fill materials. CLINICAL RELEVANCE: BBR consistently exhibited low degrees of conversion, even when the applied energy density exceeded the manufacturer's recommended levels. Further research is warranted to establish optimized curing protocols for giomer-based composites and to investigate the long-term impact of the degree of conversion on the mechanical properties and clinical durability of these restorations.

Indexed as

Composite ResinsCuring Lights, DentalLight-Curing of Dental AdhesivesHardnessIn Vitro TechniquesMaterials TestingPolymerizationSpectrum Analysis, RamanSurface PropertiesTime FactorsComposite ResinsTetric ceramBulk fill compositesDegree of conversionIrradianceMicrohardnessPolywave

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.