SynthesisAnaesthesia2025
Point-of-care ultrasound of the upper airway in difficult airway management: a systematic review and meta-analysis.
Synthesis in Anaesthesia, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07444528 (Upper Airway Ultrasound to Predict Difficult Airway Management in Neonates and Infants), which is not on this map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Upper Airway Ultrasound to Predict Difficult Airway Management in Neonates and Infants: A Prospective Observational Study
Who cites it
9 citing papers in PubMed.
- Airway and Endotracheal Tubes: Role of POCUS.Indian journal of pediatrics · 2026Review
- Tongue Thickness and Skin-to-Hyoid Distance as Ultrasonographic Markers of Difficult Airway in Patients Without Anticipated Difficulty: A Prospective Diagnostic Accuracy Study of 713 Adults.Healthcare (Basel, Switzerland) · 2026Article
- Comparison of Focused Upper Airway Ultrasonographic and Anthropometric Measurements for Predicting Difficult Intubation: A Prospective Observational Study.Medicina (Kaunas, Lithuania) · 2026Observational
- Improving bedside airway tests accuracy for predicting difficult laryngoscopy using ultrasound-measured skin-to-epiglottis distance.Journal of anesthesia, analgesia and critical care · 2026Article
- Preoperative airway ultrasonography for predicting difficult intubation in adult female patients: a prospective observational study.BMC anesthesiology · 2026Observational
- Mechanical ventilation for ICU patient with obesity: current best practices and future directions.Intensive care medicine · 2026Review
- Point-of-Care Ultrasound in Airway Management.Journal of clinical medicine · 2026Review
- Diagnostic Accuracy of Point-of-care Ultrasonography for Endotracheal Tube Confirmation: Interpreting Evidence beyond Pooled Estimates.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2026Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe utility of bedside screening tests for the prediction of difficult airways is limited. There is growing interest in the role of point-of-care-ultrasound in airway assessment and management. This systematic review and meta-analysis aimed to determine the diagnostic utility and clinical application of various upper airway point-of-care-ultrasound parameters in the prediction of difficult airways.
methodsWe searched databases for randomised controlled trials, observational studies and case series with more than five cases.
resultsIn total, 60 studies involving 10,580 patients, evaluating 58 parameters were included. For difficult facemask ventilation, a narrative synthesis showed that increased tongue thickness was associated with an increased incidence of a difficult airway. For prediction of difficult laryngoscopy, the sensitivity, specificity and area under the receiver operator characteristic curve (AUROC) for distance from-skin-to-vocal-cords were 0.84 (95%CI 0.74-0.91), 0.81 (95%CI 0.61-0.92) and 0.87 (95%CI 0.78-0.89), respectively (high certainty of evidence). For prediction of difficult tracheal intubation, distance from skin-to-epiglottis had the highest sensitivity (0.80 (95%CI 0.74-0.85)) and specificity (0.86 (95%CI 0.74-0.91)) (high certainty of evidence), while distance from skin-to-hyoid had the highest AUROC of 0.86 (95% CI 0.73-0.92), with a sensitivity and specificity of 0.78 (95%CI 0.60-0.89) and 0.81 (95%CI 0.63-0.91), respectively (moderate certainty of evidence). Ultrasound use was associated with higher first pass success in percutaneous tracheostomy (odds ratio (95%CI) 3.9 (2.1-71), (low-moderate certainty of evidence)) and improved cricothyroid membrane identification compared with palpation (odds ratio (95%CI) 3.61 (2.20-5.92) (moderate-high certainty of evidence)). DISCUSSION: Upper airway point-of-care ultrasound may improve prediction of difficult airways; its use is associated with improved first pass success in percutaneous tracheostomy. Future research should focus on evaluating its use in combination with a focused history and standard bedside examination tests, and in at-risk patient populations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.