Evidence map›Paper›PMID 40890676›Full record

ArticleBMC biotechnology2025

Magnetron sputtering to enhance bone integration of tantalum-coated titanium implants: an in vitro and in vivo analysis.

Jialiang Li, Yuxin Gong, Yuewen Xue, Zhengtuan Guo, Chong Xie, Fangfang Xu, Guangbin Zhao, Zhengjie Lin, Xijing He

Abstract read
In one paragraph

Article in BMC biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jialiang LiHonghui Hospital, Xi'an Jiaotong University, Xi'an, China.
Yuxin GongThe State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, China.
Yuewen XueDepartment of Orthopedics, The Second Affiliated Hospital of Xi'an Jiagtong University, Xi'an, China.
Zhengtuan GuoDepartment of Pediatric Surgery & Vascular Anomalies, Xi'an International Medical Center Hospital, Xi'an, China.
Chong XieDepartment of Pediatric Surgery & Vascular Anomalies, Xi'an International Medical Center Hospital, Xi'an, China.
Fangfang XuCollege of Stomatology, Xi'an Jiaotong University, Xi'an, China.
Guangbin ZhaoThe State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, China. zhaogb@xjtu.edu.cn.
Zhengjie Lin3D Printing Clinical Translational and Regenerative Medicine Center, Department of Stomatology, Shenzhen Qianhai Shekou Free Trade Zone Hospital, Shenzhen, China. linzhengjie1218@163.com.
Xijing HeDepartment of Orthopedics, The Second Affiliated Hospital of Xi'an Jiagtong University, Xi'an, China. xijing_h@vip.tom.com.

Funding

Guangdong Basic and Applied Basic Research Foundation 2023A1515220232,2022A1515011815Nanshan Science and Technology Program NSZD2024053Shenzhen Science and Technology Program JCYJ20220530151608019the Key Research and Development Program of Shaanxi 2024GX-YBXM-222,2023-YBSF-276the National Natural Science Foundation of China 52405326,82372417
6 · The paper itself

Abstract

Ti6Al4V (TC4) widely used in bone implants, has good mechanical properties but unremarkable bone-forming capacity. Tantalum (Ta) features excellent biocompatibility and suitability for osteogenesis, albeit with a significantly higher elastic-modulus. In this study, we combined the strengths of both materials to optimize implant materials. Magnetron sputtering was applied to deposit a Ta coating onto the TC4 surface (Ta-C-TC4). Surface characteristics were assessed via scanning electron microscope (SEM). Cell adhesion was assessed using SEM and cytoskeletal staining, while live/dead staining was used to evaluate cell viability and biocompatibility on the material surfaces. For proliferation analysis, fluorescence transfection and CCK-8 assay were utilized, while quantification of substance and qRT-PCR were employed to assess the osteogenic differentiation. In vivo, fluorescence labelling, VG, and Goldner staining were employed to evaluate bone integration. A 550 nm-thick Ta coating was successfully achieved on Ta-C-TC4, and its elements and morphology closely resembled Ta. Cells exhibited more pronounced proliferation and differentiation on Ta and Ta-C-TC4. More extensive encasement of new bone was observed around Ta and Ta-C-TC4. Ta-C-TC4 exhibits biocompatibility on par with Ta and demonstrates superior bone integration compared to TC4. Magnetron sputtering represents a promising strategy to harness the mechanical attributes of TC4 with the biological characteristics of Ta, thereby holding potential for the advancement of bone implant.

Indexed as

Coated Materials, BiocompatibleOsseointegrationTantalumTitaniumAlloysAnimalsCell AdhesionCell DifferentiationCell ProliferationCell SurvivalMaterials TestingOsteoblastsOsteogenesisProstheses and ImplantsSurface PropertiesAlloysCoated Materials, BiocompatibleTantalumTitaniumtitanium alloy (TiAl6V4)Bone integrationCoating technologyIn vivo experimentalMagnetron sputteringTantalum

Identifiers

PMID40890676
PMCPMC12400777

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.