Evidence map›Paper›PMID 40890461›Full record

ArticleScientific reports2025

Decoding and spatial mapping of acoustic noise in the neonatal intensive care unit.

Hanan Mukhaiber, Kinana Ali, Ebrahim Ismaiel

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Hanan MukhaiberDepartment of Biomedical Engineering, Faculty of Mechanical and Electrical Engineering, Damascus University, Damascus 86, Syria. hanan.mukhaiber72@damascusuniversity.edu.sy.
Kinana AliDepartment of Biomedical Engineering, Faculty of Mechanical and Electrical Engineering, Damascus University, Damascus 86, Syria.
Ebrahim IsmaielDepartment of Medicine and Surgery, University of Parma, Parma, 43125, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The neonatal intensive care unit (NICU) is a critical care setting where premature infants face continuous exposure to elevated noise levels, often exceeding international safety guidelines. While the risks of excessive acoustic exposure are well established, strategies for real-time noise monitoring and mitigation in operational NICUs remain underexplored. In this study, we propose an exploratory framework that integrates spatially distributed sound sensors, acoustic heatmap visualization, and machine learning-based classification to analyze and categorize noise events in a high-density NICU setting. The analysis identified persistent high-noise zones near incubators and entryways, with staff movement and alarm-related activities causing significant sound level spikes-particularly during the noon shift. Additionally, a random forest classifier achieved 85.5% accuracy in distinguishing clinical activity patterns based on environmental acoustic data. While not intended for urgent alerting, this framework demonstrates the potential of using ambient sound profiles for non-critical event recognition and environmental monitoring in the NICU.

Indexed as

AcousticsEnvironmental MonitoringIntensive Care Units, NeonatalNoiseHumansInfant, NewbornInfant, PrematureMachine LearningAcoustic mapNeonatal ICUNoiseSpatial mappingVocal intensity

Identifiers

PMID40890461
PMCPMC12402165

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.