Evidence map›Paper›PMID 40890332›Full record

ArticleEJNMMI physics2025

Optimizing dosimetry in Y-90 microsphere radioembolization: GPU-accelerated Monte Carlo simulation versus conventional methods for high-volume setting.

Liu Hongming, Liang Ziwei, Hu Ziyi, Qu Shuiyin, Hu Ankang, Yan ShuChang, Wu Zhen, Zhang Hui, Li Junli, Qiu Rui

Abstract read
In one paragraph

Article in EJNMMI physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Liu HongmingDepartment of Engineering Physics, Tsinghua University, Beijing, 100084, P. R. China.
Liang ZiweiBeijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, 102218, China.
Hu ZiyiDepartment of Engineering Physics, Tsinghua University, Beijing, 100084, P. R. China.
Qu ShuiyinDepartment of Engineering Physics, Tsinghua University, Beijing, 100084, P. R. China.
Hu AnkangDepartment of Engineering Physics, Tsinghua University, Beijing, 100084, P. R. China.
Yan ShuChangDepartment of Engineering Physics, Tsinghua University, Beijing, 100084, P. R. China.
Wu ZhenDepartment of Engineering Physics, Tsinghua University, Beijing, 100084, P. R. China.
Zhang HuiDepartment of Engineering Physics, Tsinghua University, Beijing, 100084, P. R. China.
Li JunliDepartment of Engineering Physics, Tsinghua University, Beijing, 100084, P. R. China.
Qiu RuiDepartment of Engineering Physics, Tsinghua University, Beijing, 100084, P. R. China. qiurui@tsinghua.edu.cn.ORCID http://orcid.org/0000-0002-3511-6164

Funding

National Natural Science Foundation of China 12375312National Natural Science Foundation of China U2167209National Natural Science Foundation of China U23B200085
6 · The paper itself

Abstract

backgroundYttrium-90 (

methodsA fast Monte Carlo simulation algorithm was developed using Graphics Processing Unit (GPU) acceleration and applied retrospectively to eight patients diagnosed with hepatocellular carcinoma or metastatic colorectal cancer. The dosimetric performance of the GPU-based approach was compared against direct Monte Carlo (MC) simulations, the Medical Internal Radiation Dose (MIRD) formalism, the Voxel S-value (VSV) method, and the Local Energy Deposition (LED) model. Voxel- and organ-level dose accuracy were quantified using metrics such as Mean Absolute Relative Error (MARE), Relative Standard Deviation (RSD), and D95 in dose volume histogram. Statistical comparisons were conducted using Shapiro-Wilk normality tests and repeated measures ANOVA to assess inter-method differences.

resultsThe GPU-based Monte Carlo code demonstrated high accuracy and computational efficiency. Using direct MC simulation as the reference, the GPU-based approach yielded the lowest voxel-level variability, with median RSDs in high-activity transverse regions reaching - 1.13%, indicating superior consistency. Corresponding MARE were 4.53% for the GPU method, compared to 6.71% for VSV and 49.36% for LED, confirming its dosimetric reliability. At the organ level, the GPU-based method achieved RSDs of 0.35% ± 0.80% (tumor), -0.45% ± 0.76% (liver), 1.41% ± 4.45% (lung), and - 1.43% ± 1.23% (spleen), significantly outperforming alternative models. Notably, VSV and LED substantially underestimated lung dose (-52.19% ± 23.87%, -53.71 ± 22.17%), highlighting their limited applicability in heterogeneous regions. In contrast, the dose of spleen (F = 3.26, p = 0.069) and kidneys (F = 3.22, p = 0.071) did not show statistically significant differences between methods. In terms of computational performance, the GPU-based code delivered a remarkable 1,296-fold speed-up over traditional MC simulations, enabling efficient voxel-level dosimetry suitable for clinical workflows.

conclusionThe GPU-based fast Monte Carlo simulation provides a highly accurate and computationally efficient tool for voxel-level dosimetry in CLINICAL TRIAL NUMBER: Not applicable.

Indexed as

90YDosimetryFast Monte Carlo simulationGPUNuclear medicine

Identifiers

PMID40890332
PMCPMC12401777

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.