ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2025
[A signal sensing system for monitoring the movement of human respiratory muscle based on the thin-film varistor].
Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In order to accurately capture the respiratory muscle movement and extract the synchronization signals corresponding to the breathing phases, a comprehensive signal sensing system for sensing the movement of the respiratory muscle was developed with applying the thin-film varistor FSR402 IMS-C07A in this paper. The system integrated a sensor, a signal processing circuit, and an application program to collect, amplify and denoise electronic signals. Based on the respiratory muscle movement sensor and a STM32F107 development board, an experimental platform was designed to conduct experiments. The respiratory muscle movement data and respiratory airflow data were collected from 3 healthy adults for comparative analysis. In this paper, the results demonstrated that the method for determining respiratory phase based on the sensing the respiratory muscle movement exhibited strong real-time performance. Compared to traditional airflow-based respiratory phase detection, the proposed method showed a lead times ranging from 33 to 210 ms [(88.3 ± 47.9) ms] for expiration switched into inspiration and 17 to 222 ms [(92.9 ± 63.8) ms] for inspiration switched into expiration, respectively. When this system is applied to trigger the output of the ventilator, it will effectively improve the patient-ventilator synchrony and facilitate the ventilation treatment for patients with respiratory diseases.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.