Evidence map›Paper›PMID 40885948›Full record

ArticleMicrobial cell factories2025

Mechanisms of magneto-coagulation of the sludge in activated sludge bulking processes.

Ramin Khoshniyat, Ghorban Asgari, Esmaeil Ghahramani, Glen T Daigger

Abstract read
In one paragraph

Article in Microbial cell factories, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ramin KhoshniyatEnvironmental and Occupational Health Group, Health Network of Sanandaj, Vice Chancellor for Health Affairs, Kurdistan University of Medical Sciences, Sanandaj, Iran. r.khoshniyat2023@gmail.com.
Ghorban AsgariDepartment of Environmental Health Engineering, School of Public Health, Social Determinants of Health Research Center (SDHRC), Hamadan University of Medical Sciences, Hamadan, Iran.
Esmaeil GhahramaniEnvironmental Health Research Center, Research Institute for Health Department, Kurdistan University of Medical Sciences, Sanandaj, Iran.
Glen T DaiggerDepartment of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

One of the inherent problems of activated sludge processes (ASPs) is the production of large volumes of sludge, which creates issues in secondary clarifiers regarding sludge settling. The application of physical methods such as static magnetic fields (SMFs) has attracted considerable attention from researchers in recent years regarding the sedimentation of wastewater sludge in ASPs. One basic parameter for evaluating sludge settling measurement is the rate of settling sludge in the graduated cylinder for 30 min (SV30). During the exposure of the SMFs (15 mT), sludge sedimentation with and without the use of metal coagulants was uneven in the case samples. The sludge settled in the graduated cylinder reactor had a smooth surface. The reason for uneven sedimentation of SV30 is related to the formation of Ramin’s zone between the negatively charged particles of the separated sludge blanket layers. Ramin’s zone is temporary and by increase electrostatic forces between negative ions in this area and positive ions above the upper zone, will be stronger. This interaction allows the sludge to float back up and re-sedimentation. The results of present of sludge in SV30 test and with exposure of SMFs (15 mT) by the application metallic coagulants or without them, is the uneven surface of sedimentation of the sludge. This re-sedimentation of sludge happened by use of metal coagulants, too. settling occurs because of the electrostatic attraction between negatively and positively charged particles.

Indexed as

SewageWaste Disposal, FluidFlocculationMagnetic FieldsSewageCoagulantsMechanismRamin’s zoneSludge sedimentationStatic magnetic fields

Identifiers

PMID40885948
PMCPMC12398163

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.